Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM ( Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection N Repair Inspection ❑ 36 Month Inspection <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10181655 11 /06/ 19 <br /> Business Name (Same as Facility Name or DBA-Doing Business As.) <br /> Chevron 372736 <br /> Business Site Address City ZIP Code <br /> 9484 West Ln Stockton 195210 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification) Phone # <br /> Nick Halve 916 834 - 5099 Ext, <br /> Contractor/Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 300345 A B C61040 HAZ 5115738 01 / 11 /2021 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications) <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method Used : ❑ Manufacturer Guidelines (Specify) <br /> N Industry Code or Engineering Standard (Specify) PEI RP 1200 <br /> ❑ Engineered Method (Specify) <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages : <br /> Tank ID : (By tank number, stored product, etc) 87 91 Diesel <br /> What is the tank inside diameter? (Inches) 119 92 92 <br /> Is the fill piping secondarily contained? N Yes ❑ No N Yes ❑ No Z Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained ? Z Yes ❑ No Z Yes ❑ No Z Yes ❑ No ❑ Yes ❑ No <br /> OPW OPW OPW <br /> Overfill Prevention Equipment Manufacturer(s) <br /> What is the overfill prevention equipment N Shuts Off Flow Z Shuts Off Flow N Shuts Off Flow ❑ Shuts Off Flow <br /> response when activated ? ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow <br /> (Check all that apply) ❑ AN Alarm ❑ AN Alarm ❑ AN Alarm ❑ AN Alarm <br /> Are flow restrictors installed on vent piping ? ❑ Yes N No ❑ Yes N No ❑ Yes N No ❑ Yes ❑ No <br /> At what level in the tank is the overfill prevention 107 84 84 <br /> set to activate? (Inches from bottom of tank.) <br /> What is the percent capacity of the tank at which 95 95 95 <br /> the overfill prevention equipment activates? <br /> Is the overfill prevention in proper operating N Yes Z Yes Z Yes ❑ Yes <br /> condition to respond when the substance ❑ No ❑ No ❑ No ❑ No <br /> reaches the appropriate level? (Specify in section V.) (Specify in section V.) (Specify in section V) (Specify in section V) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results N Pass ❑ Fail 11 N Pass ❑ Fail Z Pass ❑ Fail ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> All items marked "Fail" must be explained in this section. Any additional comments may also be provided here. <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations, title 23, division 3, <br /> chapter 16, section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature )(U t�+i�`Z r}I` 1' t-Ul� <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CE RS = California Environmental Reporting System, ID = Identification, UST = Underground storage tank, ICC = International Code Council, AN — Audible and visual <br />