My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
9484
>
2300 - Underground Storage Tank Program
>
PR0232601
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/28/2020 1:25:14 PM
Creation date
9/3/2020 8:54:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0232601
PE
2361
FACILITY_ID
FA0004525
FACILITY_NAME
CHEVRON STATION #372736/2223
STREET_NUMBER
9484
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09055063
CURRENT_STATUS
01
SITE_LOCATION
9484 WEST LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAHI Environmental Health Department <br /> C U NTY Time In: <br /> Time Out: <br /> ' SS grows hojr <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: CHEVRON SS #372736 Date: 11/08/2019 <br /> Address: 9484 WEST LANE , STOCKTON 95210 <br /> Requestor: LIDDY MCKENZIE, GETTLER RYAN INC. Telephone: (925) 551-7555 <br /> Program Element: 2308- UST RETROFIT Request#: SR0080446 <br /> Inspection Type: 298- UST RETROFIT REPAIR INSPECTION <br /> Onsite Service Technician: Raymond Simms ICC Service Tech/Installer Exp. Date: 06/25/2020 <br /> Manufacturer training: VMI, 12/10/20; OPW,03/14/20 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> On site for the following: <br /> -Verified monitoring system and sensors functionality-all passed <br /> -Verified system leak detector test-all passed <br /> - Overfill prevention: Verified 95% tank volume shut off. Tanks set at 95% tank volume shut off. <br /> -Verified flapper functionality. <br /> -Verified Ball Floats- No Ball floats present. Service Technician stated he removed ball floats <br /> -Verified dispenser footprints, piping and fuel filters drainage into UDCs. Deflector plates not yet installed. <br /> -Secondary containment of UST system not performed since tanks annular space is brine filled and are on continuous <br /> monitoring. <br /> NB. Secondary containment testing for the UDCs, and all product piping is required on April 2020 ( 6months after initial <br /> testing.). <br /> Provide photos of all UDCs installed with deflector plates . <br /> This facility is approved to operate the UST system. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code. If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Donald Baughn, Service Tech <br /> EH Specialist: PAUL NSO Phone: (209)468-3432 <br /> SR0080446 SC298 11/08/2019 <br /> EHD 23-01 Rev.06/30/15 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.