Laserfiche WebLink
SANJ O A Q U I N Environmental Health Department <br /> COUNTY RECEIVED FEB 19201,9 <br /> Underground IS Tank Program Inspection Report <br /> Facility Name : Facility Address : <br /> CHEVRON STATION #372736/2223Date: <br /> 9484 WEST LN, STOCKTON February 19, 2019 <br /> File Review <br /> 123 CCR 2637. 1 (d), Failure to submit the "Spill Container Testing Report Form" within 30 days after the test <br /> 263741 (e) oV o R o COS <br /> 124 CCR 2637,2(d&e), "Overfill Prevention Equipment Inspection Report Form" not submitted within 30 days of Inspection <br /> o V o R o COS <br /> On Site Records <br /> 201 CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records <br /> oV oR aCOS <br /> 202 CCR 2715(c)(3), Failure to maintain the "Facility Employee Training Certificate" on-site (after October 1 , 2018) <br /> 2715(c) (4) o V a R ❑ COS <br /> 203 CCR 2712(b) Failure to maintain records of repairs, lining, and upgrades on site, for the life of the UST <br /> a o oCOS <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site <br /> oV o oCOS <br /> 205 CCR 2712(1), 2634(e) Failure to submit a current UST Response Plan and have it available onsite <br /> oV o ❑ COS <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions <br /> oV aR oCOS <br /> 207 HSC 25294 Failed to record unauthorized release from primary containment <br /> oV a ❑ COS <br /> 208 CCR 2650(e) , 2652 Failed to notify the EHD of a reportable unauthorized release and/or prepare a report <br /> oV a ❑ COS <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days <br /> rV a oCOS <br /> 210 CCR 2716(f) DO monthly reports not maintained on site for 12 months or for 36 months (after October 1 , 2018) a V o R o COS <br /> 211 CCR 2715(c)(2) No employee present that were trained in the operation and maintenance of the UST system by a DO o V o R a COS <br /> 212 CCR 2715(f)(2) Unstaffed facility failed to have or implement a training program approved by the EHD ❑ V ❑ R ❑ COS <br /> 213 HSC 25281 .5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br /> a o oCOS <br /> 214 HSC 25281 . 5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept <br /> o o ❑ COS <br /> 215 CCR 2712(1) Failure to retain a copy of the permit to operate at the facility <br /> V a R o COS <br /> UST System Observations <br /> F30HSC 25292. 1 (a) UST system is not operated to prevent unauthorized release, including spills and overfills <br /> o o aCOS <br /> HSC 25291 (b) UST system incapable of detecting leak from primary into secondary containment (pre-Jul 2003) ❑ V oR oCOS <br /> HSC 25290.2(d) Monitoring system not maintained to detect entry Into secondary containment (Jul 2003-Jun 2004) ❑ V o R o COS <br /> 304 HSC 25290. 1 (d) Monitoring system not maintained to detect entry Into secondary containment (after Jul 2004) <br /> o o ❑ COS <br /> 305 HSC 25290. 1 (a) VPN monitoring of the interstitial spaces of the UST system Is not maintained <br /> 0 0 C3 COS <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity pPo ty ❑ V o R ❑ COS <br /> 307 CCR 2631 (g), 2632(c) Monitoring system of the interstitial space of a double walled system not maintained <br /> oV o ❑ COS <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm <br /> u o aCOS <br /> 309 CCR 2636(0(1 ) Monitoring in sump / UDC failed to activate an audible and visual alarm or stop the now product <br /> oV o oCOS <br /> 310 CCR 2638(0(4) Piping is not fail-safe outside UDCs or falls to stop flow of product at dispenser Inside UDCS <br /> oV o oCOS <br /> 311 CCR 2638(x), 26410) Failed to properly program, calibrate, operate, or maintain leak detection equipment <br /> oV oR ❑ COS <br /> 312 CCR 2638(01 2641 (1) Failed to affix a tag sticker on monitoring equipment certified, repaired, or replaced <br /> oV aR aCOS <br /> 313 HSC 25290v Is 25290. 21 Failure to construct, operate, and maintain primary containment as product-tight <br /> 25291 ■ V o R o COS <br /> EHD 23-01 Rev. 09!2812018 FAD004525 PR0232601 SC001 02/19/201g <br /> Page 2 of 6 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-34201 F 209 464-0138 1 www, sjcehd. com <br />