My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WALNUT GROVE
>
9015
>
2300 - Underground Storage Tank Program
>
PR0521738
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 12:11:41 PM
Creation date
9/3/2020 10:59:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0521738
PE
2371
FACILITY_ID
FA0014762
FACILITY_NAME
JD Service Station, Inc.
STREET_NUMBER
9015
STREET_NAME
WALNUT GROVE
STREET_TYPE
RD
City
THORNTON
Zip
95686
CURRENT_STATUS
01
SITE_LOCATION
9015 WALNUT GROVE RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM ( Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection ® 36 Month Inspection <br /> I . FACILITY INFORMATION <br /> CERS ID 10443520 Date of Overfill Prevention Equipment Inspection <br /> 19/26/ 18 <br /> Business Name (Same as Facility Name or DBA-Doing Business As.) <br /> THORNTON CHEVRON <br /> Business Site Address City ZIP Code <br /> 9015 WALNUT GROVE THORNTON) CA 95351 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br /> DAVEWINKLER 209 744 - 0112 Ext. <br /> Contractor/Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 08-1739 8883059-UT 1 -31-20 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> FF- EBW Phil-Tite & EVR Phase 1 1009853708 Ex 11 - 16- 18 OPW 104-633 Ex 3- 14-2020 Emco #3207 Ex. 09-21 -2020 VR: B34975 ATG: 2/8/20 <br /> III , OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method Used : [3d Manufacturer Guidelines (Spe6MEDER ROOT REMOVED PROBES <br /> ❑ Industry Code or Engineering Standard (Specify) <br /> ❑ Engineered Method (Specify) <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages: <br /> Tank ID : (By tank number, stored product, etc.) 87 91 DSL <br /> What is the tank inside diameter? (Inches) 11960 119 . 60 119 . 60 <br /> Is the fill piping secondarily contained? [3d Yes jNo ® Yes ❑ No ® Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained? ® Yes ❑ ® Yes ❑ No ® Yes [:] No ❑ Yes ❑ No <br /> VEEDER ROOT VEEDER ROOT VEEDER ROOT VEEDER ROOT <br /> Overfill Prevention Equipment Manufacturer(s) <br /> PROBE PROBE PROBE <br /> What is the overfill prevention equipment ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow <br /> response when activated? ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow <br /> (Check all that apply.) [N AN Alarm [M AN Alarm ® AN Alarm ❑ AN Alarm <br /> Are flow restrictors installed on vent piping? ❑ Yes ® No ❑ Yes I3d No ❑ Yes ® No ❑ Yes ❑ No <br /> At what level in the tank is the overfill prevention107 107 <br /> set to activate? (Inches from bottom of tank.) 107 <br /> What is the percent capacity of the tank at which 90 90 90 <br /> the overfill prevention equipment activates? <br /> Is the overfill prevention in proper operating ® Yes IX Yes [RYes ❑ Yes <br /> condition to respond when the substance ❑ No ❑ No ❑ No ❑ No <br /> reaches the appropriate level? (Specify in section V.) (Specify in section V.) (Specify in section V.) (Specify in section V . ) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ® Pass ❑ Fail M Pass ❑ Fail EX Pass ❑ Fail ❑ Pass ❑ Fail <br /> V . COMMENTS <br /> All items marked "Fail' must be explained in this section. Any additional comments may also be provided here. <br /> �NVIRD v a <br /> D <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations , title 23, division 3 , <br /> chapter 16, section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground storage tank, ICC = International Code Council, AN = Audible and visual <br />
The URL can be used to link to this page
Your browser does not support the video tag.