COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WALNUT GROVE
>
9015
>
2300 - Underground Storage Tank Program
>
PR0521738
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 12:11:41 PM
Creation date
9/3/2020 10:59:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0521738
PE
2371
FACILITY_ID
FA0014762
FACILITY_NAME
JD Service Station, Inc.
STREET_NUMBER
9015
STREET_NAME
WALNUT GROVE
STREET_TYPE
RD
City
THORNTON
Zip
95686
CURRENT_STATUS
01
SITE_LOCATION
9015 WALNUT GROVE RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax; (209)468-3433 Web:www.s'gov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> JD Service Station, Inc. 9015 WALNUT GROVE RD, THORNTON April 09, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> Current fnancial responsibility documents have not been submitted to the EHD. <br /> -The Certification of Financial Responsibility marks $2 million annual aggregate in Section A, but only$1 million in <br /> section C. <br /> -The Letter from the Chief Financial Officer includes asset and liability amounts that have not been updated in over <br /> five years. <br /> -The dates on both documents were whited out and rewritten, without obtaining new signatures. <br /> Current financial responsibility documents are required to be submitted annually. Immediately log into the California <br /> Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, and upload the required documents. <br /> This is a minor violation. <br /> 106 CCR 2632(d)(2), 2634(e) Failed to have an approved UST response plan. <br /> Section V of the response plan was left blank. The response plan must be uploaded to the California Environmental <br /> Reporting System (CERS). Immediately log into CERS, upload the completed form, and submit for review by the <br /> EHD. Ensure a copy is available for inspection at any time. <br /> This is a minor violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. The map submitted in CERS shows an inaccurate sump <br /> layout for the 91 and diesel tanks, does not include annular sensors, and lists an incorrect street name east of the <br /> facility. A site plan must be submitted identifying the locations where monitoring will be performed. Immediately log <br /> into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/and upload a copy of the <br /> UST Monitoring Site Plan. <br /> This is a minor violation. <br /> 113 CCR 2638(c), 2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the <br /> test. <br /> Annual monitoring system certification, leak detector testing, and spill container testing was performed on 4/23/18 <br /> and a test report was submitted on 7/11/18, two months late. A copy of the test report must be submitted within 30 <br /> days of the tests. Take all necessary precautions to ensure testing and submittal of test reports are performed in a <br /> timely manner. <br /> This is a minor violation. <br /> FA0014762 PRO521738 SCO01 04/09/2019 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 8 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.