My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
121
>
2300 - Underground Storage Tank Program
>
PR0543446
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/20/2022 11:41:30 AM
Creation date
9/3/2020 4:16:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0543446
PE
2351
FACILITY_ID
FA0024656
FACILITY_NAME
7-ELEVEN #38153
STREET_NUMBER
121
Direction
S
STREET_NAME
CENTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
121 S CENTER ST
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUNDSTORAGETANK <br />OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br />Type of Action Installation Test r Repair Test 36 Month Test <br />1. FACILITY INFORMATION <br />CERS ID <br />10770799 <br />Date of Overfill Prevention <br />4/19/2019 <br />Equipment Inspection: <br />Business Name (Same as Facility Name or DBA -Doing Business As.) <br />7 -Eleven 38153 <br />Business Site Address <br />121 S. Center Street <br />City: <br />Stockton <br />Zip: <br />95202 <br />IL UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br />Name of UST Service Technician Performing the Test (Print as shown on the ICC Certification.) <br />Jesus Saldivar <br />Phone # <br />(800) 800-4633 <br />Contractor/Tank Tester License # <br />Class A General Engineering 743160 <br />ICC Certification # <br />8361393 <br />ICC Certification Expiration Date <br />6/16/2019 <br />Spill Container Testing Training and Certifications (List applicable certifications.) <br />ICC - CA UST Service Technician 8361393 06/16/2019 <br />III, OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br />Manufacturer Guidelines (Specify) <br />Test Method Used: rv, Industry Code or Engineering Standard (Specify) PEI RP 1200 <br />F Engineered Method (Specify) <br />Attach the testing procedures and all documentation required to determine the results. <br /># of <br />1 <br />Attached Pages: <br />Tank ID: (By tank number, stored product, etc.) <br />REG. <br />PREM. <br />DIESEL <br />What is the tank inside diameter? (Inches) <br />118.38 in. <br />118.38 in. <br />118.38 in. <br />Is the fill piping secondarily contained? <br />r Yes r No <br />W Yes r No <br />F Yes r No <br />r Yes No <br />Is the vent piping secondarily contained? <br />r Yes r No <br />F Yes r No <br />r Yes r No <br />r Yes r No <br />Overfill Prevention Equipment Manufacturer(s) <br />OPW <br />OPW <br />OPW <br />OPW <br />OPW <br />What is the overfill prevention equipment response <br />when activated? (Check all that apply.) <br />I+/ Shuts Off Flow <br />r Restrict Flow <br />r A/V Alarm <br />Shuts Off Flow <br />r Restrict Flow <br />r AA/ Alarm <br />F Shuts Off Flow <br />r Restrict Flow <br />r AA/ Alarm <br />r Shuts Off Flow <br />r Restrict Flow <br />r AA/ Alarm <br />Are flow restrictors installed on vent piping? <br />W Yes r No <br />r Yes r No <br />r Yes r No <br />r Yes r No <br />At what level in the tank is the overfill prevention set to <br />activate? (Inches from bottom of tank.) <br />105.375 <br />106.125 <br />104.625 <br />What is the percent capacity of the tank at which the <br />overfill prevention equipment activates? <br />94.4 <br />94.5 <br />94.2 <br />Is the overfill prevention in proper operating condition <br />to respond when the substance reaches the <br />appropriate level? <br />W Yes <br />r No <br />(Spesify in section V) <br />r Yes <br />r No <br />(Spesify in section V) <br />Yes <br />r No <br />(Spesify in section V) <br />r Yes <br />r No <br />(Spesify in section V) <br />N. SUMMARY OF TESTING RESULTS <br />Overfill Prevention Inspection Results <br />W Pass r Fail <br />W Pass r Fail <br />r Pass r Fail <br />r Pass r Fail <br />V. COMMENTS <br />All items marked failed above must be explained in this section. Any additional comments may also be provided here. <br />VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS <br />1 hereby certify that the spill containers were tested in accordance with California Code of Regulations, title 23, division <br />2637.1 and all the information contained herein is accurate. <br />3, chapter 16, section <br />UST Service Technician Signature <br />4A ° w� <br />If the facility has more components than this form accommodates, additional copies of this page may be attached. <br />CERS=California Environmental Reporting System, ID=Identification, UST=Underground storage tank, ICC=International Code <br />Council <br />
The URL can be used to link to this page
Your browser does not support the video tag.