My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1229
>
2300 - Underground Storage Tank Program
>
PR0527041
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/25/2020 2:39:17 PM
Creation date
9/8/2020 11:17:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0527041
PE
2351
FACILITY_ID
FA0018327
FACILITY_NAME
MANTECA GAS & FOOD*
STREET_NUMBER
1229
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
20809015
CURRENT_STATUS
01
SITE_LOCATION
1229 E LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A J OA U I Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MANTECA GAS & FOOD* 1 1229 E LOUISE AVE, MANTECA August 20, 2020 <br /> Other Violations <br /> 2010 1 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 107 CCR 2632(d), 2641(h), 2711(a) Plot plan/site map not submitted or failed to completely show where monitoring is <br /> performed. <br /> OBSERVATION: An accurate UST Monitoring Site Plan was not submitted. <br /> -A site plan must be submitted identifying the locations where monitoring is performed ( Monitoring panel). <br /> REGULATION GUIDANCE: Asite plan must be submitted identifying the locations where monitoring will be <br /> performed. The site plan must show the general layout of tanks and piping and clearly identify locations of the <br /> following equipment, if installed: 1) monitoring system control panels; 2) in-tank liquid level probes (if used for leak <br /> detection); 3) devices monitoring tank annular spaces or vault; 4) devices monitoring product piping; 5) devices <br /> monitoring fill piping; 6) devices monitoring vent piping; 7)devices monitoring vapor recovery piping; 8) devices <br /> monitoring vent/transition sumps; 9) devices monitoring under-dispenser containment; 10) line leak detectors; and <br /> 11) devices monitoring any other secondary containment areas. <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This is a minor violation. <br /> 115 CCR 2715(a)(1)(B), 2715(a)(3)"Designated Underground Storage Tank Operator Identification Form" not submitted <br /> within 30 days. <br /> OBSERVATION: The designated Underground Storage Tank operator identification form was not found in CERS. <br /> REGULATION GUIDANCE: The owner or operator shall submit a "Designated Underground Storage Tank Operator <br /> Identification Form" no later than 30 days after any change in the designated UST operator(s). <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov and upload the notification identifying all the designated operators for this facility. <br /> This is a minor violation. <br /> FA0018327 PR0527041 SCO01 08/20/2020 <br /> EHD 23-01 Rev.8/11/2020 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.