My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
141
>
2300 - Underground Storage Tank Program
>
PR0543574
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2020 10:47:39 AM
Creation date
9/8/2020 2:12:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0543574
PE
2351
FACILITY_ID
FA0024750
FACILITY_NAME
76 FUEL ISLAND & CARWASH
STREET_NUMBER
141
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
CURRENT_STATUS
03
SITE_LOCATION
141 E HARNEY LN
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SA N A A Q U I N Environmental Health Department <br /> ---COUNTY <br /> F. SYSTEM PIPING CONTINUED: <br /> Check Code <br /> Box Section <br /> HSC Piping compatible with material intended to be stored. <br /> Ek 25290.1 c 1 <br /> 25290.2 c 1 <br /> 23 CCR <br /> 1 2631(b) Design and construction of piping approved by independent testing organization(e.g. UL). <br /> Piping, including vent lines, sloped toward tank(s)with minimum 1/8 inch slope per 1 foot of run. <br /> HSC <br /> 5 90.1 k Vapor recovery, fill riser, and vent line piping are secondarily contained. <br /> Fk 25290.2�c�&Q) <br /> G. OVERSPILL/ OVERFILL PREVENTION: <br /> Check <br /> Box Section <br /> 23 CCR Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br /> IX 2635(b) Manufacturer Model <br /> Phil-Tice M42-2C-1-0-NPR <br /> Approved overfill prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> ❑ Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> ❑ Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the <br /> 23 CCR restriction occurs when the tank is filled to no more than 95 percent capacity; and activate an <br /> 2635(b)(2) audible alarm at least five minutes before the tank overfills <br /> IR Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> ❑ Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling. <br /> Manufacturer ESW/Franklin Fueling Model 708592902 <br /> H. CORROSION PROTECTION: <br /> Check Code <br /> Box Section <br /> R Fiberglass reinforced plastic(FRP) <br /> Piping corrosion protection: ❑ Steel with cathodic protection or impressed current <br /> Fk 23 CCR ❑ Steel isolated from contact with backfill <br /> 2636(b) <br /> 5t FRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: ❑ Sacrificial Anode <br /> 23 CCR <br /> 2635(a)(2) ❑ Steel tank with field installed cathodic protection or impressed <br /> current <br /> Tie-downs,when used, constructed of non-corrosive material or coated steel. <br /> 7of8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.