My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
141
>
2300 - Underground Storage Tank Program
>
PR0543574
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2020 10:47:39 AM
Creation date
9/8/2020 2:12:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0543574
PE
2351
FACILITY_ID
FA0024750
FACILITY_NAME
76 FUEL ISLAND & CARWASH
STREET_NUMBER
141
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
CURRENT_STATUS
03
SITE_LOCATION
141 E HARNEY LN
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Anchor Designer TM Company: Cullumber Engineering Date: 5/16/2018 <br /> Engineer: C. Dilworth Page: 4/4 <br /> Software Project: Lodi-Fuel Tanks <br /> Version 2.5.6582.0 Address: <br /> Phone: <br /> E-mail: <br /> 8.Steel Strength of Anchor in Shear(Sec.17.5.11 <br /> Vaa(Ib) ¢9ro,,, 0 Og..[Ovsa(lb) <br /> 16080 1.0 0.65 10452 <br /> 9.Concrete Breakout Strength of Anchor in Shear(Sec.17.5.21 <br /> Shear parallel to edge in y-direction: <br /> Vbx=min17(4/da)021daxia�f'cca1'S;9ilaJfcca,'51(Eq. 17.5.2.2a&Eq.17.5.2.2b) <br /> /a(in) da(in) A. fc(psi) ca,(in) Vbx(lb) <br /> 7.00 0.875 1.00 2500 12.00 18706 <br /> OV cby=0(2)(Avc/Avco)Ped,vY'c,vV'h.vVbx(Sec. 17.3.1,17.5.2.1(c)&Eq.17.5.2.1 a) <br /> Avc(in 2) Avco(in 2) Yed,v 9o,v Ph.v Vbx(lb) 0 OVcby(Ib) <br /> 648.00 648.00 1.000 1.000 1.000 18706 0.70 26189 <br /> 10.Concrete Pryout Strength of Anchor in Shear(Sec.17.5.31 <br /> OVcp=Okc^b=okcp(ANc/ANco)y'ed,NV'oNy'op.NNb(Sec. 17.3.1 &Eq.17.5.3.1a) <br /> kcp AN.(in 2) ANco(int) P.d,N TN Pop.N Nb(lb) 0 OVcp(lb) <br /> 2.0 1199.97 1296.00 0.900 1.000 1.000 50318 0.70 58703 <br /> 11.Results <br /> Interaction of Tensile and Shear Forces(Sec.17.6.1 <br /> Tension Factored Load,Nva(lb) Design Strength,oNn(lb) Ratio Status <br /> Steel 13914 20096 0.69 Pass(Governs) <br /> Concrete breakout 13914 29352 0.47 Pass <br /> Pullout 13914 56910 0.24 Pass <br /> Shear Factored Load,Via(lb) Design Strength,aVF(lb) Ratio Status <br /> Steel 1164 10452 0.11 Pass(Governs) <br /> 11 Concrete breakout x+ 1164 26189 0.04 Pass <br /> Pryout 1164 58703 0.02 Pass <br /> Interaction check N„a/0Na V„a/0Va Combined Ratio Permissible Status <br /> Sec. 17.6..1 0.69 0.00 69.2% 1.0 Pass <br /> PAB7(7/8"0)with hef=12.000 inch meets the selected design criteria. <br /> 12.Warnings <br /> -Designer must exercise own judgement to determine if this design is suitable. <br /> Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. <br /> Simpson Strong-Tie Company Inc. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com <br /> 6of10 <br />