My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
141
>
2300 - Underground Storage Tank Program
>
PR0543574
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2020 10:47:39 AM
Creation date
9/8/2020 2:12:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0543574
PE
2351
FACILITY_ID
FA0024750
FACILITY_NAME
76 FUEL ISLAND & CARWASH
STREET_NUMBER
141
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
CURRENT_STATUS
03
SITE_LOCATION
141 E HARNEY LN
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Why Choose Our Fiberglass Sump? <br /> For decades, ZCL I Xerxes has established itself throughout North America as a leading manufacturer of long-life,corrosion- <br /> resistant fiberglass vessels and accessories that offer superior protection for the environment.The internal environment of <br /> containment sumps is very corrosive.The use of ethanol, ultra-low sulfur diesel(ULSD)and biodiesel fuels, and the corrosion <br /> damage caused by these fuels and resulting vapors is increasing. Our fiberglass containment sumps offer customers a <br /> corrosion-resistant, long-term option for the storage of liquids in underground installations. <br /> A Variety of Sump Options <br /> Whether a customer is installing a new underground system or is retrofitting an existing installation, containment sumps are <br /> used on nearly all double-wall tanks today.We supply containment collars and sumps as a package to provide secondary <br /> containment around tank fittings, piping, pumps and manways. Customers have the option of either dry interstitial <br /> monitoring or hydrostatic monitoring. Most double-wall containment sump installations are equipped with hydrostatic <br /> monitoring for the same reasons that customers choose it as a monitoring method for double-wall tanks—continuous <br /> monitoring of both walls 24/7. Our containment sumps come in a variety of models, sizes and cover/top options. <br /> MODELS & MONITORING COVER/TOP SIZE <br /> OPTIONS OPTIONS OPTIONS <br /> • Round and flat-sided 32-inch watertight cover • 42-inch diameter <br /> • Double-wall sump with 38-inch watertight cover • 48-inch diameter <br /> hydrostatic monitoring 32-inch friction-fit cover • 36-inch to 72-inch height <br /> • Double-wall sump with dry Open top option • Available in shallow and deep <br /> monitoring burial heights <br /> • Single-wall sump <br /> THE ZCL I XERXES ADVANTAGE <br /> ZCL I Xerxes double-wall underground storage tanks offer customers several significant design and performance <br /> differences that make them a superior choice to both steel tanks and other fiberglass tanks. <br /> • Corrosion-Resistant Inside and Out • Maintenance-Free <br /> • 100% Premium Resin and Glass • TRUCHEK®Continuous Leak Detection <br /> • Flexible Design and Installation Options • 30-Year Limited Warranty <br /> FUEL COMPATIBILITY CORROSION RESISTANCE <br /> Our UL-listed(1316)and ULC-listed(S615)double-wall ZCL I Xeres tanks and sumps are made of fiberglass,which <br /> fiberglass tanks are listed as compatible with 0-100 percent means they are inherently resistant to corrosion. Because they <br /> ethanol storage and warranted for the full range of ethanol- are corrosion-resistant inside and out,you'll have the peace <br /> blended gasoline. Since the UL listing for steel tanks does not of mind of choosing products that help preserve and protect <br /> require ethanol compatibility testing,this is another distinct the environment.You'll also enjoy a lower cost of ownership <br /> advantage of fiberglass over steel. than with steel tanks,which corrode over time and require <br /> PARABEAM® maintenance. <br /> To create a double-wall sump that is structurally strong,ZCL I EXTENSIVE THIRD-PARTY QUALITY TESTING <br /> Xeres uses Parabeam®,our patented 3D glass-reinforcement As further evidence of their durability, ZCL I Xerxes double- <br /> material,to bond the sump walls.This is the same design wall sumps have passed extensive third-parry testing to verify <br /> concept that has made our double-wall tanks the most widely that they withstand interstitial pressure levels that other <br /> used underground tanks in North America. By using our sumps cannot.Therefore, customers can be assured that <br /> unique woven-glass to create the interstitial space,our sumps our containment sumps are superior to other options in the <br /> are built to avoid weaknesses such as structural collapse and marketplace. <br /> false monitoring alarms due to flexing walls. <br />
The URL can be used to link to this page
Your browser does not support the video tag.