COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
141
>
2300 - Underground Storage Tank Program
>
PR0543574
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2020 10:47:39 AM
Creation date
9/8/2020 2:12:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0543574
PE
2351
FACILITY_ID
FA0024750
FACILITY_NAME
76 FUEL ISLAND & CARWASH
STREET_NUMBER
141
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
CURRENT_STATUS
03
SITE_LOCATION
141 E HARNEY LN
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9-20-2018 <br /> 141 E Harney Lane <br /> List of Outstanding Issues: <br /> 1) Please provide installer/contractor information (on your application form) and submit all <br /> relevant installer/tester certifications <br /> 2) Provide fire permit number(on your permit application form) <br /> 3) Provide a copy of the ELD workplan <br /> 4) Provide cut sheets for all proposed parts on your pats list,for example tank cut sheets are still <br /> needed- tank installation instructions were provided in lieu of the tank cut sheets <br /> 5) Clarify which leak detector will be used and provide its cut sheet. FE Petro cut sheet was not <br /> provided and FE Petro was listed on the application, however, Veeder Root PLLD was listed your <br /> the parts list <br /> 6) Application lists 42"sumps, however parts list lists 42"and 48"sumps, please clarify <br /> 7) Please clarify if chase lines will be installed between fill and STP sumps and if these lines will be <br /> VPH monitored, please provide revised sheets to demonstrate this. For example G.0.1 shows <br /> chase pipe on 87 UST but G.1.0 doesn't show that pipe. Also the general pipe layout is different <br /> between these sheets and on G.1.0, vent pipe to 12K tank ends abruptly before the sump. <br /> 8) G.0.1 table lists some values as Vvalue!"please clarify <br /> 9) Ensure that all liquid sensors are installed at the lowest points,for example on G.4.0 the 208 <br /> sensor is not shown at the lowest point. On G.6.0 (vent sump detail), no Veeder Root 208 sump <br /> sensor bottom is visible due to the proposed sensor sleeve set up. <br /> 10) Please clarify how VPH piping communication will be tested, no apparent ports of valves or <br /> provisions to test communication on a routine basis were observed.Also on G.5.0, "end view"a <br /> hose is exiting the secondary containment penetration and terminates without leading <br /> anywhere, please correct and resubmit. No communication test port is visible on G.6.0 vent sump <br /> drawing, please clarify if communication test port will be installed on the vent piping termination <br /> inside the vent sump. Vacuum and brine monitoring provisions must be illustrated on UDC, vent <br /> and tank sump cross-sections <br /> 11) Bravo sumps are listed on the parts list, however, page 8 of 8 of the permit application lists OPW <br /> Flex Works, please clarify. <br /> 12) Please clarify if Veeder Root 350 or 350 Plus will be used, it appears to be used intermittently on <br /> the plans. <br /> 13) On page G.7.1 a single point annular sensor is being proposed(instead of the dual high and low <br /> sensor), please revise and resubmit. Also on the same G.7.1 only one FE Petro leak detector is <br /> being listed, clarify which leak detectors will be installed on 87/91 tanks, revise the parts list to <br /> reflect the correct system inventory <br /> 14) Please point out the spill containers and their water-tight VPH shields on the parts list and their <br /> reference number on drawings, please provide drawing reference where water tight construction <br /> is detailed or provide a revised drawing illustrating the water tight construction of all sumps. <br /> 15) Confirm that the UDC foot print will match the dispensers foot print and all piping and filters will <br /> drain directly into respective UDC without any retrofit modifications, please provide a reference <br /> to that effect on your plans <br />