My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
1405
>
2300 - Underground Storage Tank Program
>
PR0231485
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2021 11:15:13 AM
Creation date
9/8/2020 2:19:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231485
PE
2361
FACILITY_ID
FA0000306
FACILITY_NAME
EMILS LIQUOR & SPORTS SHOP*
STREET_NUMBER
1405
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
ESCALON
Zip
95320
APN
22707031
CURRENT_STATUS
01
SITE_LOCATION
1405 CALIFORNIA ST
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
06 / 28 / 2019 19 : 29 8387674 EMILS PAGE 23 <br /> UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM Page 5 of 6 <br /> XII . LINE LEAK DETECTOR TESTING <br /> ❑ Check this box if line leak defectors (LLD) are NOT Installed . (Do not complete this section.) y N NA <br /> This section must be completed if LLUS are Installed <br /> Was a leak simulated to verify LLD performance? Q El El <br /> (Check ail that apply.) Simulated leak rate verified : ❑X 3 OPH ❑ 0. 11 GPH <br /> E] 0.2 GPH <br /> Was the testing apparatus properly calibrated ? X ❑ ❑ <br /> For emergency generator tank systems , does the LLD create an audible and visual alarm when a leek is detected ? ❑ ❑ <br /> For mechanical LLDs, does the LLD restrict the flow through the pipe when a leak is detected? N ❑ ❑ <br /> For electronic LLDs , does the turbine automatically shut off when a leak is detected ? El <br /> For electronic LLDs , does the turbine automatically shut off if any portion of the monitoring system fa disabled or disconnected ? ❑ � X <br /> For electronic LL.Ds , does the turbine automatically shut off if any portion of the monitoring system malfunctions or falls a test? ❑ El X <br /> For electronic LLDs, have all accessible wiring connections been vllsually inspected for kinks and breaks? ( ❑ X❑ <br /> Wen: all items on the equipment manufacturer's maintenance checklist completed? rz <br /> Were all LL Ds confirmed operational within regulatory requiremonls? JN ❑ ❑ <br /> For any answer of "N" above, describe in Sectlon Xlll how and when these issvea were or will be corrected_ <br /> X111 . COMMENTS <br /> XIV. VACUUM / PRESSURE / HYDROSTATIC MONITORING EQUIPMENT TESTING <br /> ❑X Check this box if VPH monitoring Is NOT used . (Po not complete this section.) <br /> This section must be completed if VPH monitoring is used to perform leak defection monitoring. <br /> System Type (Mark all that apply.) ❑ Vacuum ElPressure ❑ Hydrostatic <br /> Component(5) Monitored B This sensor Sensor Functionality Interstitial Communication <br /> Sensor ID y Test Test <br /> ❑ Pass ❑ Fail ❑ Pass Fail <br /> �r ❑ Pass ❑ Feil ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass _ ❑ Fail <br /> ❑ Pass ❑ Fail Pass ❑ Fail <br /> ❑ Pass ❑ Fall Pass ❑ Fail <br /> ❑ Pass Fail ❑ Pass OEM <br /> Pass ❑ Fail Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fall ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> Pess Faii ❑ pass ❑ Fail <br /> How was interstitial communication verified? ❑ Simulated Leak at Far Ends of the Interstitial Space ❑ Visual Inspection <br /> Other (Describe the method in section XV below. Gauge <br /> Was the vacuum or pressure restored to operating levels in all interstitial spaces ? Ellos ❑ No (Describe the reason in section XV below. <br /> For any answer of "f=ail" above, describe in Sectlon XV how And when these issues were or will be corrected. <br /> XV. COMMENTS <br /> GPH = Gallons Per Hour, Y = Yes, N = No, NA = Not Applicable, VPH = VacvumiPcsssurelHydrostatic, ID = Identification <br /> Received Time Jun , 28 . 2019 1 : 27PM No , 5223 <br />
The URL can be used to link to this page
Your browser does not support the video tag.