Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM (Page 1 of 6) <br /> Type of Action ❑Installation Test ❑Repair Test ❑Six Month Test ❑x 36 Month Test <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10180529 2/28/2019 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> J&L Market <br /> Business Site Address City ZIP Code <br /> 8115 South EI Dorado Street French Camp 95231 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test(Print as shown on the ICC Certification) Phone# <br /> Benjamin Duncan (707) 621-0378 <br /> Contractor!Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> Afford-a-test/90-1120 5246802-UT 1 4/3/2019 <br /> III. SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID:(By tank number,stored product, etc.) A T-1-87 B T-2-91 C T-3-Diesel D <br /> Tank Containment <br /> Tightness Test Result E Pass ❑ Fail ❑NA E Pass ❑ Fail ❑NA E Pass ❑Fail ❑ NA ❑ Pass ❑Fail ❑NA <br /> Product Piping Containment <br /> Tightness Test Result O Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑NA O Pass ❑Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail O NA ❑Pass ❑Fail E NA ❑Pass ❑Fail E NA ❑ Pass ❑Fail ❑NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail p NA ❑Pass ❑Fail O NA ❑Pass ❑Fail p NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑ Pass ❑ Fail E NA ❑Pass ❑ Fail E NA ❑Pass ❑ Fail E NA ❑ Pass ❑Fail ❑NA <br /> Vent Piping Containment <br /> Tightness Test Result ❑ Pass ❑Fail E NA ❑Pass ❑Fail E NA ❑Pass ❑Fail p NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑ Pass ❑ Fail E NA ❑Pass ❑ Fail E NA ❑Pass ❑Fail O NA ❑ Pass ❑ Fail ❑NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑ Pass ❑Fail E NA ❑Pass ❑ Fail E NA ❑Pass ❑Fail E NA ❑Pass ❑ Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail E NA ❑Pass ❑ Fail E NA ❑Pass ❑Fail E NA ❑Pass ❑ Fail ❑NA <br /> Turbine/Product Piping Sump <br /> Tightness Test Result O Pass ❑Fail ❑NA E Pass ❑ Fail ❑NA E Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑NA <br /> Fill Riser Sump <br /> Tightness Test Result ❑ Pass ❑ Fail E NA ❑Pass ❑Fail E NAI ❑Pass ❑ Fail E NA ❑ Pass ❑Fail ❑NA <br /> VENT/TRANSITION SUMP ID: a b C d <br /> Tightness Test Result ❑Pass ❑Fail E NA ❑Pass ❑Fail O NA ❑Pass ❑ Fail E NA ❑Pass ❑Fail O NA <br /> UDC ID: 1 1&2 2 3&4 3 5&6 4 7&8 <br /> Tightness Test Result E Pass ❑Fail ❑NA E Pass ❑Fail ❑NA p Pass ❑Fail ❑ NA E Pass ❑Fail ❑NA <br /> UDC ID: 5 6 7 8 <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑ Fail ❑NA ❑ Pass ❑Fail ❑ NA <br /> UDC ID: 9 10 11 12 <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> All items marked"Fail'or"NA"must be explained in their respective"COMMENTS"section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> hereby certify that the secondary containment was tested in accordance with California Code of Regulations,Title 23,Division <br /> 3,Chapter 16,Section 2637 and all the informations contained herein is accurate. <br /> UST Service Technician Signature `inlsa .'`a1Juf2caez� <br /> CERS=Califomia Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,NA=Not Applicable,UDC=Under- <br /> Dispenser Containment <br />