SANJ OA U I Environmental Health Department <br /> COUNTY <br /> — <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> J & L MARKET 8115 S EL DORADO ST FRENCH CAMP May 22 2019 <br /> Other Violations <br /> 2010 1 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. <br /> -UDC leak sensor model was left blank. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a repeat violation, Class II. <br /> 115 CCR 2715(a)(1)(B), 2715(a)(3)"Designated Underground Storage Tank Operator Identification Form" not submitted <br /> within 30 days. <br /> Dave Winkler is performing designated operator inspections at this facility and is not listed on the statement of <br /> designated operator. Any changes shall be reported to the EHD within 30 days. Immediately log into the California <br /> Environmental Reporting System (CERS) at http://cers.calepa.ca.gov and upload the notification identifying all the <br /> designated operators for this facility. <br /> This is a repeat violation, Class II. <br /> 201 CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br /> Maintenance and monitoring records for the last three years were not found on site. <br /> -Overfill prevention test results for 1/25/19 were not found on site. <br /> These records shall be maintained on site for at least three years. Monitoring records include: (1)date and time of all <br /> monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any visual <br /> observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other <br /> monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings and <br /> reconciliations. A copy of the results was emailed by the tester at the time of inspection. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 204 CCR 2712(1) Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be accessible <br /> on site at all times. Immediately locate and retain a copy on site. <br /> This is a repeat violation, Class II. <br /> FA0000110 PR0231563 SCO01 05/22/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 Of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />