My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
15600
>
2300 - Underground Storage Tank Program
>
PR0231585
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2021 11:26:03 AM
Creation date
9/10/2020 9:59:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231585
PE
2361
FACILITY_ID
FA0000174
FACILITY_NAME
JOES TRAVEL PLAZA
STREET_NUMBER
15600
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19620079
CURRENT_STATUS
01
SITE_LOCATION
15600 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑Installation Inspection ❑Repair Inspection ❑x 36 Month Inspection <br /> 1. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10180541 10/1/2018 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Joes Travel Plaza <br /> Business Site Address City ZIP Code <br /> 15600 S Harlan Rd Lathrop 95330 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the/CC Certification) Phone# <br /> David Winkler 1 (209) 744-0112 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 08-1739 Ex.3/31/2020 8883059-UT 1/29/2020 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> FF- EBW, Phil-Tite & EVR Phase 1 1009853708 Ex 11-16-18 OPW 104-633 Ex 3-14-2020 <br /> Emco #3207 Ex. 09-21-2020 VR: B34975 ATG:2/8/20 <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION IN N <br /> Inspection Method ❑x Manufacturer Guidelines(Specify): <br /> Used: Removed Drop Tubes FEB 12 R19 <br /> ❑Industry Code or Engineering Standard(Specify): <br /> ❑Engineered Method(Specify): <br /> ENVIRONMENTAL HEALT <br /> Attach the inspection procedures and all documentation required to determine the results. #of 1MFPAPb-6W=N 15 <br /> TANK ID:(By tank number,stored product,etc.) 87 W 87 E 91 DSL <br /> What is the tank inside diameter?(Inches) 114 95 114 114 <br /> Is the fill piping secondarily contained? ❑Yes ❑x No ❑Yes ❑x No ❑Yes I] No ❑Yes 0 No <br /> Is the vent piping secondarily contained? Exl Yes ❑No ❑x Yes ❑No 0 Yes ❑No ❑x Yes ❑No <br /> Overfill Prevention Equipment Manufacturer(s) oPw OPw oPw oPw <br /> 61-SO 61-SO 61-SO 61-SO <br /> What is the overfill prevention equipment response ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ARestricts Flow 9Restricts Flow 0 Restricts Flow [ERestricts Flow <br /> ❑A/V Alarm ❑A/V Alarm ❑A/V Alarm ❑A/V Alarm <br /> Are flow restrictors installed on vent piping? ❑Yes (]No ❑Yes E No ❑Yes 0 No ❑Yes Eig No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(Inches from bottom of tank.) 99.5 85 10621/4 971/2 <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 92 94 94 91 <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑x Yes ❑x Yes ❑x Yes <br /> to respond when the substance reaches the <br /> El level? No(Specify in V.) ❑ No(Specify in V.) No(Specify in V.) No(Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ❑x Pass ❑Fail ❑x Pass ❑Fail 11 ❑x Pass ❑Fail ❑x Pass ❑Fail <br /> V. COMMENTS <br /> Any items marked"Fair must be explained in this section. Any additional comments may also be provided here. <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations,Title 23, <br /> Division 3, Chapter 16, Section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature V z� -"' <br /> If the facility has more components than this form accommodates,additional copies of this page may be attached. <br /> CERS=Ca6fomia Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,AA1=Audible and Visual <br />
The URL can be used to link to this page
Your browser does not support the video tag.