My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
10878
>
2300 - Underground Storage Tank Program
>
PR0231598
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:14 PM
Creation date
9/10/2020 10:04:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231598
PE
2361
FACILITY_ID
FA0001146
FACILITY_NAME
MORADA CHEVRON FAST N EASY #60*
STREET_NUMBER
10878
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08607002
CURRENT_STATUS
01
SITE_LOCATION
10878 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ OA U I Environmental Health Department <br /> —C 0U NTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MORADA CHEVRON FAST N EASY#60* 1 10878 N HWY 99 E , STOCKTON April 11, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 211 CCR 2715(c)(2) No employee present that were trained in the operation and maintenance of the UST system by a <br /> DO. <br /> No facility trained employee was found on site during inspection. The designated operator employee training was not <br /> performed or current . For facilities that are not routinely staffed, the designated operator shall implement an <br /> employee training program approved by the EHD. Ensure that employees have been trained by the designated <br /> operator, maintain the list on site, and submit a copy of the training records to the EHD. <br /> This is a minor violation. <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The 91 north STP sump sensor was not located to detect a leak at the earliest opportunity. The sensor was located on <br /> the side opposite the fuel piping and was placed over a foot south of the lowest point. Monitoring equipment shall be <br /> maintained to be able to detect a leak at the earliest possible opportunity. The sensor was relocated to the lowest point <br /> of the sump by the service technician. Ensure that all monitoring equipment is maintained to detect a leak at the <br /> earliest opportunity. <br /> This is a repeat violation, Class II. <br /> 319 CCR 2635, 2637.1, 2665, 2712 No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be <br /> tested. <br /> The 91 north spill container failed to have a minimum capacity of five gallons. All spill containers shall have a <br /> minimum capacity of five gallons. Immediately contact a properly licensed, trained, and certified contractor to repair <br /> or replace the spill container under permit and inspection of the EHD. <br /> The 87 spill container failed when tested. All spill containers shall have a minimum capacity of five gallons and be <br /> capable of containing a spill or overfill until it is detected or cleaned up. Immediately discontinue deposition of <br /> petroleum into this tank until the component is repaired or replaced by a properly licensed, trained, aand certified <br /> contractor under permit and inspection by EHD. If the spill container cannot be replaced immediately, there is a <br /> possibility that the 87 UST system may be red tagged to prevent fuel inputs. <br /> This is a minor violation. <br /> 331 CCR 2630(d), 2641(a) Liquid does not flow into the sump in the event of a leak (i.e.,failure to remove test boot).. <br /> The plug under the clamshell on the 91 south STP sump product piping was not removed. The Schrader valve was <br /> open, but was pointed up. Any potential release from the primary containment into the secondary containment in the <br /> 91 south piping does not flow into a collection sump. All secondary containment system shall be sloped so that all <br /> release will flow to a collection sump located at the low point of the underground piping. Immediately contact a <br /> properly licensed trained and certified contractor to ensure that any releases in the 91 south piping flows into the 91 <br /> south piping sump. <br /> This is a repeat violation, Class II. <br /> FA0001146 PR0231598 SCO01 04/11/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 6 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 f 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.