My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
10878
>
2300 - Underground Storage Tank Program
>
PR0231598
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:14 PM
Creation date
9/10/2020 10:04:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231598
PE
2361
FACILITY_ID
FA0001146
FACILITY_NAME
MORADA CHEVRON FAST N EASY #60*
STREET_NUMBER
10878
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08607002
CURRENT_STATUS
01
SITE_LOCATION
10878 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UST THERMOMETER TEST (cont. ) <br /> UST #3 § 7 . 3 . 3 <br /> T5 temperature <br /> T4 temperature <br /> Difference between T5 and T4 temperatures 0 . 00 <br /> Is the difference less than 10° F ? If not, proceed to section 9 . 1 <br /> § 9. 1 <br /> T5 temperature <br /> Calibrated thermometer ambient temperature <br /> Difference between T5 and calibrated thermometer 0 . 000 <br /> Is the difference less than 10° F? If not, the T5 thermometer does not meet specifications <br /> UST #4 § 7 . 3 .3 <br /> T5 temperature <br /> T4 temperature <br /> Difference between T5 and T4 temperatures 0 . 000 <br /> Is the difference less than 10 ° F? If not, proceed to section 9 . 1 <br /> § 9 . 1 <br /> T5 temperature <br /> Calibrated thermometer ambient temperature <br /> Difference between T5 and calibrated thermometer 0 . 000 <br /> Is the difference less than 10° F? If not, the T5 thermometer does not meet specifications <br /> ATMOSPHERIC PRESSURE SENSOR TEST <br /> Atmospheric pressure sensor reading (psi ) 0 . 05 <br /> Atmospheric pressure sensor reading ( in . mercury) 30 . 03 <br /> Atmospheric pressure from local source ( in . mercury) 29 . 98 <br /> Difference between local source and pressure sensor reading (A) - 0 . 05 <br /> 0 . 10 x local source (B ) 3 . 00 <br /> Is A < B ? If not, the vapor polisher is not is compliance Yes <br /> NOTES : Conversion from pressure (psi) to pressure (in . mercury) is : (psi + 14. 7) x 2 . 036 <br /> I declaz4e, under penalty of pe7jzzzy under the lcmis of the state of California that based on information and belief formed <br /> cfter reasonable inphy, the statements and information provided in this doczzment ai *e true , accurate, and complete. <br /> Signature of Technician : ��/�� Date : 10/2/2019 <br />