My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
13975
>
2300 - Underground Storage Tank Program
>
PR0231622
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:33 AM
Creation date
9/10/2020 10:40:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231622
PE
2351
FACILITY_ID
FA0000055
FACILITY_NAME
TESORO (SPEEDWAY) #68150
STREET_NUMBER
13975
Direction
E
STREET_NAME
STATE ROUTE 88
City
LOCKEFORD
Zip
95237
APN
01908014
CURRENT_STATUS
01
SITE_LOCATION
13975 E HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix C <br /> HOW TO LOCATE THE POSITION OF THE 71 SO FOR COMPLETE SHUT-OFF AT A GIVEN TANK CAPACITY <br /> Note : This Appendix only applies when AHJ require- EXAMPLE <br /> ments call for complete shut-off at a given tank capacity. 1 . For an Owens-Corning Model G-3 Fiberglass' Tank <br /> See page 4 for standard measurements . Calibration Chart : <br /> The length of the upper tube and the placement of the Tank Capacity - 10,000 gal ., nominal 9,403 gal . <br /> 71 SO valve body determine the shut-off point. The sam- NOTE : Use actual capacity only <br /> pie calculation below will provide for complete shut-off <br /> at 95 % . In all cases, the upper tube length must be a Tape measure <br /> minimum of & 1 /2 " plus the length of the riser pipe . All <br /> length measurements are in inches . <br /> INSTRUCTIONS <br /> 1 . Find the tank capacity (in gallons) from the tank cali- <br /> bration chart provided by the tank manufacturer. Riser Pipe <br /> with Face �A) <br /> 2 . Calculate 95 % of capacity. Q �� Is Seal Adaptor To Tank � <br /> e <br /> 3 . Locate the 95 % volume number on the tank calibra- Top ( l - D, ) To Tank <br /> tion chart. 00 .. + 5 Bottom <br /> 4 . Find the dipstick number (X) which corresponds to <br /> the 95 % tank volume. And , find the dipstick number <br /> (Y) which corresponds to the 100 % volume . ii l 3 /% <br /> 5 . Subtract the dipstick number (X) from the tank diam- <br /> eter (Y) to find the upper tube reference number (Z) . <br /> (Y) - (X) — (Z) Ii $ _ .3 }- tj • - ► l) I� , } 5 � • 2 . 95 % of actual tank capacity = 0 .95 x 9403 gal . _ <br /> 6 . Add 1 . 5 " to (Z) to find the upper tube depth E. 8933 gal . <br /> (Z) + 1 .5 = E j i . > 6 5 — 2 = C� > b 3 . The closest number which is less than 8933 gal . Is <br /> 7 . Is E less than 6- 1 /2" ? 8910 gal . Choosing the closest number less than <br /> 95 % of actual capacity ensures that complete <br /> NO Upper tube length is E plus the distance from the shutoff will occur when the tank is no more than <br /> top of the Face Seal Adaptor installed on the riser 95 % full . <br /> pipe to the inside, top lip of the storage tank (A) . <br /> � S � ( 4. The calibration chart reading of 8910 gal . corre- <br /> sponds to a dipstick measurement of 82 " . <br /> For testable models only, ending in "T": 5 . Dipstick number (X) = 82" <br /> Upper Tube Length = E + (A) — 1 - 1 /2 " Tank diameter (Y) = 92 " <br /> M - (X) _ (Z) (92 "- 82 = 10 ") <br /> (Z) = 10 " <br /> YES Upper tube length is 6- 1 /2" plus the riser pipe <br /> 6 . (Z) + 1 .5 " = E ( 10 " + 1 .5 " = 11 .5 ") <br /> measurement (A) . <br /> E = 11 .5 " <br /> Upper Tube Length = 6- 1 /2 " + (A) <br /> 7 . Is 11 . 5 " less than 6- 1 /2 " ? <br /> For testable models only, ending in "T" : NO Measure the distance from the top of the FSA-400 <br /> Upper Tube Length = 6- 1 /2" + (A) — 1 A /2' Face Seal Adaptor installed on the riser pipe to <br /> the inside, top lip of the storage tank and obtain <br /> measurement (A) . <br /> NOTE : You must find the actual tank capacity num - Upper tube length — E + (A) <br /> bey that correlates to the 6- 1 /2 " + (A) depth for the <br /> station records . This number may also be used or For testable models only, ending in "T": <br /> the purposes of calibrating an electronic tank level Upper Tube Length = E + (A) — 1 A /2 " <br /> system . <br /> 23 <br />
The URL can be used to link to this page
Your browser does not support the video tag.