Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection is 36 Month Inspection <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10180519 8/28/19 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> Shell #68150 <br /> Business Site Address City ZIP Code <br /> 13975 E Hwy 88 Lockeford 95237 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the JCC Certification.) I Phone # <br /> Brian McPheely (408) 971 -2445 <br /> Contractor I Tank Tester License # F88�22062 <br /> C Certification # ICC Certfcation Expiration Date <br /> 485184 111 / 19/19 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> B36745 <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method V1 Manufacturer Guidelines (Specify): <br /> Used : Veeder Root <br /> ❑ Industry Code or Engineering Standard (Specify): <br /> ❑ Engineered Method (Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages <br /> TANK ID : (By tank number, stored product, etc.) I -Reg 2-Prem 3-DSL <br /> What is the tank inside diameter? (Inches) 120 120 120 <br /> Is the fill piping secondarily contained ? p Yes ❑ No W1 Yes ❑ No [0 Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained? ® Yes ❑ No 10 Yes ❑ No ® Yes ❑ No ❑ Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) Veeder Root Veeder Root Veeder Root <br /> What is the overfill prevention equipment response ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ElRestricts Flow ElRestricts Flow ❑ Restricts Flow ElRestricts Flow <br /> m AN Alarm IZI AN Alarm m AN Alarm ❑ AN Alarm <br /> Are flow restrictors installed on vent piping ? ❑ Yes © No ❑ Yes © No ❑ Yes [Z No ❑ Yes ❑ No <br /> At what level in the tank is the overfill prevention set <br /> to activate? (inches from bottom of tank.) 107 .875 107 .375 108 .625 <br /> What is the percent capacity of the tank at which the o 90% 90% <br /> overfill prevention equipment activates? 90% <br /> Is the overfill prevention in proper operating condition O Yes ® Yes la Yes ❑ Yes <br /> to respond when the substance reaches the <br /> E appropriate level? ❑ No (Specify in V) ❑ No (Specify in V.) ❑ No (Specify in V.) ❑ No (Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results 0 Pass ElFail 0 Pass ❑ Fail OF ass ❑ Fail El Pass ❑ Fail <br /> _ V. COMMENTS <br /> Any items marked "Fail" must be explained in this section. Any additional comments may also be provided here. <br /> Vi . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipmentwas inspected in accordance with California Code of Regulations, Title 233 <br /> Division 3, Chapter 16, Section 2637. 2 and all the Information contained herein is accurate. <br /> UST Service Technician Signature <br /> ff the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = Intemational Code Council, AN Audible and Visual <br /> r <br /> I <br /> I <br />