Laserfiche WebLink
oPnu' SAN ) 0 A Q U I N Environmental Health Department <br /> Jr <br /> " 1- '6; COUNTY Linda Turkatte, REHS , Director <br /> � eKase Foley, REHS Assistant Director <br /> IF,0 Greatness grows here . y y> > <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> Michael Kith , REHS <br /> October 2 , 2019 Melissa Nissim , REHS <br /> Kristin Nappen <br /> Walton Engineering , Inc . <br /> P . O . Box 1025 <br /> West Sacramento , CA 95691 <br /> Re : Speedway #4492 SR0080922 <br /> 2132 Mariposa Rd . , Stockton , CA 95205 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of the <br /> application for a 1 hour plan check service request to repair the UDC penetrations (with split retrofit <br /> penetrations that do not require concrete breaking , piping disconnection , or sump/piping modification ) <br /> on the underground storage tank ( UST) system at the above noted address , _.The plan check service <br /> request has been approved with the following conditions : <br /> 1 . Contact the local fire departmenfand the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust( sjgov . org for the following repairs and testing ( a 48 - hour <br /> notice is required ) . Please be aware that inspections for emergency work must be scheduled <br /> within five days of plan check service request approval . <br /> a . Secondary containment testing on UDCs <br /> 4 . Secondary containment testing for the UDCs is required six months after installation . Provide <br /> 48 hours notification to the EHD when this test is scheduled . <br /> 5 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor's licenses issued by the Contractors State License Board (may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board , and <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service Technician <br /> certificate issued by the International Code Council ( ICC) , and <br /> c . Possesses a valid , current certificate of training from the manufacturer(s) of the <br /> component (s) being tested , repaired , or serviced . <br /> 6 . Individuals installing underground storage tank system components must possess or work <br /> under the direct and personal supervision of an individual physically present at the work site <br /> who possesses all of the following : <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 F 209 464-0138 1 www. sjgov. org/ehd <br />