6421
>
2300 - Underground Storage Tank Program
>
PR0231706
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/5/2022 4:02:03 PM
Creation date
9/10/2020 2:35:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231706
PE
2361
FACILITY_ID
FA0000485
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95242
APN
05532024
CURRENT_STATUS
01
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br />OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br />Type of Action ❑ Installation Inspection ❑ Repair Inspection 0 36 Month Inspection <br />I. FACILITY INFORMATION <br />CERS ID Date of Overfill Prevention Equipment Inspection <br />10180605 1/29/19 <br />Business Name (Same as Facility Name or DBA -Doing Business As) <br />FLAG CITY CHEVRON <br />Business Site Address City ZIP Code <br />6421 Capital Ave I Lodi 95242 <br />II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br />Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br />Edward Stearns (209) 744-0112 <br />Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br />14-1760 Ex. 09/30/2020 8883080 -UT 11/9/2020 <br />Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br />FF- EBW , PhikTite & EVR Phase 1 1009893708 Ex 11/29/2020 OPW 104-635 Ex 3-14-2020 <br />Emco 3205 Ex. 11/16/2020 ATG: VR A31048 Ex.8/9/19 Incon 1009893708 11/30/2020 <br />111. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br />Inspection Method El Manufacturer Guidelines (Specify): remove and inspected <br />Used: <br />❑ Industry Code or Engineering Standard (Specify): <br />❑ Engineered Method (Specify): <br />Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages 4 <br />TANK ID: (By tank number, storedproduct, etc.) 91 87 MASTER 87 SLAVE DIESEL <br />What is the tank inside diameter? (Inches) 96 96 96 96 <br />Is the fill piping secondarily contained? ❑ Yes x❑ No ❑ Yes EINo ❑ Yes H No ❑ Yes Z No <br />Is the vent piping secondarily contained? ❑ Yes N No ❑ Yes E]No ❑ Yes Z No ❑ Yes N No <br />Overfill Prevention Equipment Manufacturer(s) OPW OPW OPW OPW <br />61 SO 61 SO 61 SO 61 SO <br />What is the overfill prevention equipment response❑x Shuts Off Flow [] Shuts Off Flow ❑x Shuts Off Flow Z Shuts Off Flow <br />when activated? <br />(Check all that apply) ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow <br />❑ A/V Alarm ❑ A/V Alarm ❑ AIV Alarm ❑ A/V Alarm <br />Are flow restrictors installed on vent piping? ❑ Yes H No ❑ Yes ❑X No ❑ Yes [E No ❑ Yes ❑x No <br />At what level in the tank is the overfill prevention set <br />to activate? (Inches from bottom of tank.) 85 80.00 80.00 80.00 <br />What is the percent capacity of the tank at which the <br />overfill prevention equipment activates? 97 93 93 93 <br />Is the overfill prevention in proper operating condition ❑x Yes 0 Yes (] Yes ❑x Yes <br />to respond when the substance reaches the <br />appropriate level? ❑ No (Specify in V.) ❑ No (Specify in V) [:]No (Specify in V.) ❑ No (Specify in V.) <br />IV. SUMMARY OF INSPECTION RESULTS <br />Overfill Prevention Inspection Results ❑ Pass ❑x Fail E] Pass ❑ Fail Z Pass ❑ Fail ❑x Pass ❑ Fail <br />V. COMMENTS <br />Any items marked "Fail' must be explained in this section. Any additional comments maj#j'alse providgd here. <br />91 DROP TUBE FLAPPER SET TO HIGH. <br />z <br />i{ ! p ggnn <br />VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br />I hereby certify that the overfill prevention equipmentwas inspected in accordance wry 6hr11fCot1hIh/t19djbjof 2d, rl irO s, Title 23, <br />Division 3, Chapter 16, Section 2637.2 and all the information contained herein is accurate.,- r � ,� rr psi_ <br />UST Service Technician Signature <br />If the facility has more components than this form accommodates, additional copies of this page maybe attached. <br />CERS = California Environmental Reporting System, ID = Identification, UST =Underground Storage Tank, ICC = International Code Council, AA/ Audible <br />and Usual <br />
The URL can be used to link to this page
Your browser does not support the video tag.