Laserfiche WebLink
Page of <br /> 8 . FILL RISER CONTAINMENT_ SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps <br /> Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br /> Test Method Developed By : D Sump Manufacturer 0 Industry Standard x Professional Engineer <br /> ❑ Other (Specify) <br /> Test Method Used : D Pressure C Vacuum x Hydrostatic <br /> D Other (Specifj) <br /> Test Equipment Used : Caldwell Level Change htdicatoi Equipment Resolution : . 002 <br /> .757 7r-;... .n. .._.... rwr . ..,- w ..; ,. .„= . _ :,.k... _. <br /> Fill Sump # 1 87 Fill Sump #2 87 Fill Sump #3 Diesel Fill Sump #4 91 <br /> Save Master — -- <br /> Sump Diameter _ 42 — -- 42" 42 42" <br /> Sum De the <br /> 55 " 52" 51 3/1 49> > <br /> Height from 'Tank Top to Top of 21 " 18" 21 " 18' <br /> Hi hest Pi ) in Penetration : <br /> Height from Tank Top to Lowest i 32" 32" 32" 32 <br /> Electrical Penetration : <br /> Condition of sump prior to DRY DRY DRY DRY <br /> testing: <br /> Portion of Sjunn Tested Water Line 25" Water Line 22 " Water Line 25" Water Line 22" <br /> Sump Material : FRP FRP FRP FRP <br /> Wait time between applying 5 Minutes 5 Minutes 5 minutes 5 Minutes <br /> pressure/vacuum/water and <br /> startin test: _ <br /> Test Start Time: 11 :25 a.m . 12_: 05 .m . 12 :45 p . m . 10 : 40 a .m . <br /> Initial Readin R� : . 001 .001 . 001 . 001 <br /> Test End Time : 11 : 55 a . m . 12 : 35 m . m . 1 : 15 p . m , 1 I : 10 a. m . <br /> _Final Reading (Rr) : .001 .00 t . 001 . 001 <br /> Test Duration : 30 Minutes 30 Minutes 30 Minutes 30 Minutes <br /> Change in Reading (R3• - Ri) : 0 0 0 0 <br /> Pass/Fail Threshold or Criteria: .005/30 Minutes . 005/30 Minutes .005/30 Minutes . 005/30 Minutes <br /> Test Result: x Pass D Fail x Pass D Fail x Pass 0 Fail x Pass ❑ Fail <br /> Is there a sensor in the sump? x Yes 0 No x Yes D No x Yes D No x Yes ❑ No <br /> Does the sensor alarm when <br /> either product or water is x Yes D No [INA x Yes ❑ No DNA x Yes DNo DNA x Yes ❑ No DNA <br /> detected ? <br /> Was sensor removed for testing? x Yes ❑ No 0 NA x Yes ;,] No DNA x Yes D No D NA x Yes ❑ No DNA <br /> Was sensor properly replaced and x Yes 0 No 0 NA x Yes D No DNA x Yes ❑ No DNA x Yes D No DNA <br /> verified functional after testing,? _ <br /> Comments — (include information on r:T!�Yr• s made prior to testing and reconrnrende( follorn- up for failed tests) <br />