My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2020 4:51:42 PM
Creation date
9/10/2020 4:41:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�� PEI/ 111` 1200 - 17 <br /> sump , where it can be easily observed or detected prevent water from entering the interstitial space <br /> by a sensor.t of double- walled piping. Without these fittings , <br /> the integrity of the sump cannot be tested using <br /> This section describes it hydrostatic test method , this method . <br /> There are vacuum test methods available for con S. If interstitial monitoring sensors are present <br /> tainment sumps. Consult the manufacturer before within the containment sumps , tertlporat <br /> performing a vacuum test . rily <br /> remove them before conducting the test . If the. <br /> NOTE : Follow the manufacturers instructions sensor is removed . reposition after testing tel <br /> double appropriate position according to the nhanufac - <br /> when testing the interstitial spaces of <br /> walled containment sumps . ulrer ' s insu�rctions . <br /> 6 . Ir tile containment sump is found to have cracks . <br /> 6 . 5 .2 Purpose . This section describes the prepa- loose parts or separation of any joints or penetra - <br /> ration and procedures to test the integrity of con - tion fittings , it is not considered to be liquid- <br /> tainment sumps to ensure that they do not leak . tight . This visually indicates a test failure . <br /> 6 . 5 .3 Description of Test . The containment <br /> inment <br /> sump is filled to the proper level with wale )90 The CAUTION : Water can damage electrical <br /> water level is measured at the beginning and end of connections , Ensure that there are no <br /> tike test . components that can be damaged by the <br /> addition of water to the sump, if such <br /> 6 . 5 .4 Test Equipment . Test equipment shall components are present, take appropriate <br /> include : precautions when performing the test or <br /> use an alternative test method . <br /> • water; _ <br /> • measuring stick that is accurate ah within 1 / 16 <br /> (0 .063 ) inch and of sufficient length ; <br /> • stopwatch or other time- measurement device <br /> capable of measuring a I -second increment . <br /> 6 . 5 . 5 Preparation . <br /> Mier ElEdrt� M <br /> Level Jur,CC�.+n <br /> 1. Care should be taken when conducting the test ao% <br /> in the rain or during freezing weather condi - <br /> Coadwl <br /> tions . <br /> 2 . Remove and properly dispose of any liquid and Product <br /> debris ( leaves , sediment and trash ) in the con- P'P" 119 <br /> tainment sump. <br /> 3 . Inspect the containment sump for damage . <br /> Examine all penetration fittings , conduits , jtutc- FIGURE 6-5 . The test fluid level in the under dispenser <br /> tion boxes , caps and risers ( if present ) , and side - containment (UDC) must be at least 4 inches above the <br /> will seams for defects , damage or improperly highest sump penetration or sidewall seam. <br /> installed components . If there are loose com- <br /> ponents (c .g . , loose penetration linin;: clamps <br /> or missing interstitial space caps ) , correct these 6 . 5 . 6 Test Procedure . <br /> items before performing the integrity test . If 1 . Benin the test by adding water to the sump to a <br /> there are items that must be repaired or replaced minimum of 4 incites above the highest sump <br /> ( e . g . , deteriorated penetration fitting hoots ) , penetration or sump sidewall scant , whichever is <br /> rlotify the owner/operator and obtain approval higher. To compensate for sump deflection , the <br /> prior to proceeding with repairs . water must be allowed to settle a minimum of <br /> 4 . Test boots or secondary containment tcrmina 15 minutes before taking the initial test measure- <br /> tion fittings must be present on the piping pen meat . If the (highest sump penetration or sump <br /> etrating the sump. During testing, these littings sldet"dill scant is less than 4 inches from the top <br /> peLorg <br />
The URL can be used to link to this page
Your browser does not support the video tag.