Laserfiche WebLink
Environmental Health DepartmentUnderground Storage Tank Program Inspection ReportDate:November 12, 2019Facility Address:6009 N EL DORADO ST, STOCKTONFacility Name:ARCO AM/PMUST System Observations313□ V □ R □ COSFailure to construct, operate, and maintain primary containment as product-tightHSC 25290.1, 25290.2, 25291314□ V □ R □ COSFailed to have secondary containment or secondary containment not tightHSC 25290.1, 25290.2, 25291315□ V □ R □ COSWater in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003)HSC 25291(e)316■ V □ R ■ COSSecondary containment not constructed to prevent water intrusion (after Jul 2003)HSC 25290.1(c3), 25290.2(c3)317□ V □ R □ COSLine leak detector (LLD) not installedCCR 2636, 2643(c)(1), 2666(f)318■ V □ R ■ COSLeak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inchCCR 2666(c), 2643(c)(1)319□ V □ R □ COSNo spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be testedCCR 2635, 2637.1, 2665, 2712320□ V □ R □ COSFailure to comply with the installation, inspection, or record keeping of the overfill preventionCCR 2635, 2637.2, 2665, 2712321□ V □ R □ COSOverfill prevention was overriddenCCR 2635(c)(1)322□ V □ R □ COSUnburied below grade emergency generator system failed to meet exemption statusHSC 25281.6(a)323□ V □ R □ COSUnburied below grade UST system failed to meet exemption statusHSC 25283.5(a)324□ V □ R □ COSTampered with red tagCCR 2717.1(g)325□ V □ R □ COSDeposited or allowed deposit of petroleum or a hazardous substance into a red tagged USTCCR 2717.1(f), 25292.3(c)326□ V □ R □ COSTampered with or disabled leak detection devices or alarmsHSC 25299(a)(9)327□ V □ R □ COSUST system not compatible with the substance storedCCR 2631.1, 2660(m)328□ V □ R □ COSFailed to comply with temporary closure requirementsHSC 25298329□ V □ R □ COSFailed to comply with all permanent closure requirementsHSC 25298; CCR 2670, 2672330□ V □ R □ COSNo LLD on the emergency generator that restricts or shuts off the flow or triggers an alarmCCR 2636(f), 2666(c), 2666(f)331□ V □ R □ COSLiquid does not flow into the sump in the event of a leak (i.e., failure to remove test boot).CCR 2630(d), 2641(a)332□ V □ R □ COSPrimary and/or secondary containment not constructed in accordance with the established standardsCCR 2631(b&d), 2666(b&e)333□ V □ R □ COSFailure to comply with the cathodic protection system requirementsCCR 2635, 2636(b), 2662, 2712334□ V □ R □ COSSingle-walled pipe not upgraded to double-walled interstitially monitored pipe during repairCCR 2666(b)(2)335□ V □ R □ COSEquipment or methods used to monitor the UST system are not certified by an independent third-partyCCR 2630, 2632, 2643, 2644.1336□ V □ R □ COSOwner/operator allowed dispensing from a UST that has a red tag affixed to the fill pipeHSC 25292.3(c)(1)(C)Single-Walled Non-Pressurized Piping401□ V □ R □ COSSuction piping not properly sloped or incorrectly located check valveCCR 2636(a)(3), 2641(b)402□ V □ R □ COSFailure to conduct monitoring / maintain records for single-walled conventional suction (pre-1984)CCR 2643(d)403□ V □ R □ COSFailure to conduct 0.1 gph test for single-walled conventional suction systems (pre-Jan 1984)CCR 2643(d), 2661(f)404□ V □ R □ COS0.1-gph line test for single-walled gravity piping not performed biennialy or post repair (pre-1984)CCR 2643(e), 2661(f)FA0024188 PR0542116 SC001 11/12/2019EHD 23-01 Rev. 9/20/2019Underground Storage Tank Program OIRPage 3 of 71868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com