My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2905
>
2300 - Underground Storage Tank Program
>
PR0231952
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2021 4:22:52 PM
Creation date
9/14/2020 3:21:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231952
PE
2351
FACILITY_ID
FA0003712
FACILITY_NAME
CHEVRON STATION #94275*
STREET_NUMBER
2905
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09760004
CURRENT_STATUS
01
SITE_LOCATION
2905 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> COUNTY - <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address : Date: <br /> CHEVRON STATION #94275* 2905 W BENJAMIN HOLT DR , STOCKTON June 12 , 2019 <br /> UST System Observations <br /> 314 HSC 25290. 13 25290.21 Failed to have secondary containment or secondary containment not tight ❑ V ❑ R ❑ COS <br /> 25291 <br /> 315 HSC 25291 (a) Water in secondary containment not removed , analyzed, and properly disposed of (pre-Jul 2003) ❑ V ❑ R ❑ COS <br /> 316 HSC 25290A (c3) 3 Secondary containment not constructed to prevent water intrusion (after Jul 2003) ■ V ❑ R ❑ COS <br /> 25290 . 2(c3) <br /> 317 CCR 2636 , 2643(c) (1 ) , Line leak detector (LLD) not installed ❑ V ❑ R ❑ COS <br /> 2666 (f) <br /> 318 CCR 2636(1)(2) Leak detector failed to detect a 3. 0 gallons per hour leak at 10 pounds per square inch ❑ V ❑ R ❑ COS <br /> 319 CCR 2635 , 2637. 1 , No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tested ❑ V ❑ R ❑ COS <br /> 2665 , 2712 <br /> 320 CCR 2635 , 2637.21 Failure to comply with the installation, inspection , or record keeping of the overfill prevention ❑ V ❑ R ❑ COS <br /> 2665, 2712 <br /> 321 CCR 2635(b) (2) Overfill prevention was overridden ❑ V ❑ R ❑ COS <br /> 322 HSC 25281 .6 (a) Unburied below grade emergency generator system failed to meet exemption status ❑ V ❑ R ❑ COS <br /> 323 HSC 25283. 5 (a) Unburied below grade UST system failed to meet exemption status ❑ V ❑ R ❑ COS <br /> 324 CCR 2717A (g) Tampered with red tag ❑ V ❑ R ❑ COS <br /> 325 CCR 2717A (f) Deposited petroleum into a red tagged UST ❑ V ❑ R ❑ COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑ V ❑ R ❑ COS <br /> 327 CCR 2631 . 1 UST system not compatible with the substance stored ❑ V ❑ R ❑ COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑ V ❑ R ❑ COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements ❑ V ❑ R ❑ COS <br /> 330 CCR 2636 (1) 2 2666 (c) , No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm ❑ V ❑ R ❑ COS <br /> 2666 (f) <br /> 331 CCR 2630(d) , 2641 (a) Liquid does not flow into the sump in the event of a leak (i .e. , failure to remove test boot). ❑ V ❑ R ❑ COS <br /> 332 CCR 2631 (b&d) , Primary and/or secondary containment not constructed in accordance with the established standards ❑ V ❑ R ❑ COS <br /> 2666 (b&e) <br /> 333 CCR 2635, 2636(b) , Failure to comply with the cathodic protection system requirements ❑ V ❑ R ❑ COS <br /> 2662 , 2712 <br /> 334 CCR 2666(b) (2) Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair ❑ V ❑ R ❑ COS <br /> 335 CCR 2630, 2632, 2643 , Equipment or methods used to monitor the UST system are not certified by an independent third-party ❑ V ❑ R ❑ COS <br /> 2644. 1 <br /> Single-Walled Non -Pressurized Piping <br /> 401 CCR 2636(a) (3) , Suction piping not properly sloped or incorrectly located check valve ❑ V ❑ R ❑ COS <br /> 2641 (b) <br /> 402 CCR 2643(d) No monitoring or record maintenance for single-walled conventional suction systems (pre-Jan 1984) . ❑ V ❑ R ❑ COS <br /> 403 CCR 2643(d) , 2661 (f) Failure to conduct 0. 1 gph test for single-walled conventional suction systems (pre-Jan 1984) ❑ V ❑ R ❑ COS <br /> 404 CCR 2643(e) , 2661 (1) Biennial 0. 1 gph line integrity test for single-walled gravity piping not performed (pre-Jan 1984) ❑ V ❑ R ❑ COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑ V ❑ R ❑ COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR - Notice to Comply) <br /> FA0003712 PR0231952 SCO01 06/12/2019 <br /> EHD 23-01 Rev. 09/28/2018 Page 3 of 5 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468-3420 I F 209 464-0138 1 www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.