My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2905
>
2300 - Underground Storage Tank Program
>
PR0231952
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2021 4:22:52 PM
Creation date
9/14/2020 3:21:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231952
PE
2351
FACILITY_ID
FA0003712
FACILITY_NAME
CHEVRON STATION #94275*
STREET_NUMBER
2905
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09760004
CURRENT_STATUS
01
SITE_LOCATION
2905 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JOAQUIN Environmental Health Department <br /> SAN_ <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON STATION #94275* 2905 W BENJAMIN HOLT DR, STOCKTON June 12 2019 <br /> Single-Walled Non-Pressurized Piping <br /> 404 CCR 2643(e), 2661(7) Biennial 0.1 gph line integrity test for single-walled gravity piping not performed(pre-Jan 1984) V R COS <br /> Other Violations <br /> 2010 See below Unlisted General violation V R COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS ll,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 103 HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> An approved copy of financial responsibility documents were not available for inspection. Financial documents on site <br /> are outdated. A copy of these documents shall be accessible on site at all times. Immediately locate and retain a <br /> copy on site. <br /> This is a minor violation. <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The following was observed on the designated operator's monthly inspection report: <br /> -The 10/25/18 designated operator inspection report was not signed by owner/operator within 48 hours. <br /> During the visual inspection, the designated operator shall check all required testing and maintenance for the UST <br /> system have been completed and shall check all required items on the report. Ensure that designed operators <br /> performing visual inspections at this facility are including all of the required information on the reports. <br /> This is a minor violation. <br /> 316 HSC 25290.1(c3), 25290.2(c3) Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br /> A small amount of liquid was found in the 87-prouduct fill sump and 91-product STP sump. Secondary containment <br /> shall be constructed to prevent any water intrusion into the system by precipitation, infiltration, or surface runoff. The <br /> service technician removed approximately 2 oz of liquid from the both sumps and returned the sensors to their proper <br /> location. Immediately contact a properly licensed, trained, and certified contractor to address the water intrusion into <br /> the 87-prouduct fill sump and 91-product STP sump. <br /> This was corrected on site. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> The monitoring system certification was conducted on 2/25/2019 and was not witnessed by EHD. <br /> Onsite to look inside all sumps and UDCs and verify sensor locations. Paperwork inspection was completed <br /> today, 6/12/2019. A complete report was provided at that time. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> FA0003712 PR0231952 SC001 06/12/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.