My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10715
>
2300 - Underground Storage Tank Program
>
PR0541281
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/6/2024 10:53:44 AM
Creation date
9/14/2020 3:26:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0541281
PE
2361 - UST FACILITY
FACILITY_ID
FA0023650
FACILITY_NAME
Trinity Parkway AMPM ARCO #83819
STREET_NUMBER
10715
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
Stockton
Zip
95219
APN
6602002
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
10715 Trinity PKWY Stockton 95219
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ OA U I Environmental Health Department <br /> COUNTY <br /> — <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Trinity Parkway AMPM ARCO#183819 10715 Trinity Pkwy, Stockton Aril 26 2019 <br /> Other Violations <br /> 2010 1 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information form for the diesel tank is not current in CERS. <br /> -The vapor recovery primary and secondary containment were left blank. <br /> Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br /> update the required information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. <br /> -The map did not include the 91 or diesel leak detectors. <br /> A site plan must be submitted identifying the locations where monitoring will be performed. Immediately log into the <br /> California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/and upload a copy of the UST <br /> Monitoring Site Plan. <br /> This is a minor violation. <br /> 111 CCR 2638(a) & (b), 26410) Failed to test monitoring and leak detection equipment annually. <br /> Annual monitoring system certification and leak detector testing were last performed in March 2018 and was <br /> completed on April 26, 2019 , one month past due. These tests are required once every 12 months. Take all <br /> necessary precautions to ensure testing is performed in a timely manner. <br /> This is a Class II violation. <br /> 113 CCR 2638(c), 2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the <br /> test. <br /> A monitoring system certification, leak detector testing, and spill container testing were performed in March 2018. <br /> Alarm logs indicate all sensors were tested on March 23, 2018. A test report has not been submitted to the EHD or <br /> the California Environmental Reporting System (CERS). A copy of the test report must be submitted within 30 days <br /> of the test. Immediately provide this report to the EHD. <br /> This is a minor violation. <br /> FA0023650 PRO541281 SCO01 04/26/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 Of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.