Laserfiche WebLink
Appendix VI <br /> ( Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http : //www, waterboards . ca . gov . ) <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6. 7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment . A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work . A copy of this form must be provided to the tank system <br /> owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date . <br /> A. General Information <br /> Facility Name: Arco Bldg . No . : <br /> Site Address : 1904 daniels St . City: Manteca Zip : 95337 <br /> Facility Contact Person : Contact Phone No. : <br /> Make/Model of Monitoring System : TLS-350R Dale of Testing/Seryicing : 4- 17-2018 <br /> B . Inventory of Equipment Tested/Certified <br /> Check thea ro riate boxes to indicatespecific equipment ins ected/seryiced : <br /> Tank ID : 87 Unleaded Tank ID : Diesel <br /> ® In -Tank Gauging Probe . Model : 847390- 109 ® In-Tank Gauging Probe. Model : 847390- 109 <br /> ® Annular Space or Vault Sensor. Model : Hydrostatic ® Annular Space or Vault Sensor, Model : Hydrostatic <br /> ® Piping Sump / Trench Sensor(s ) . Model : 794380-208 ® Piping Sump / Trench Sensor(s ) , Model : 794380-208 <br /> ® Fill Sump Sensor(s ) . Model : 794380-208 ® Fill Sump Sensor(s ), Model : 794380-208 <br /> ❑ Mechanical Line Leak Detector. Model : ❑ Mechanical Line Leak Detector. Model : <br /> ® Electronic Line Leak Detector. Model : 8484 ® Electronic Line Leak Detector, Model : 8484 <br /> ® Tank Overfill / High- Level Sensor. Model : 847390- 109 W/Buzzer ® Tank Overfill / High-Level Sensor. Model : 847390- 109 W/Buzzer <br /> ❑ Other (specify equipment t e and model in Section E on Page 2 ) . ❑ Other (specify equipment t e and model in Section E on Page 2). <br /> Tank ID : 91 Premlum Tank ID : <br /> ® In -Tank Gauging Probe , Model : 847390- 109 ❑ In-Tank Gauging Probe . Model : <br /> ® Annular Space or Vault Sensor. Model : Shares Diesel ❑ Annular Space or Vault Sensor. Model : <br /> ® Piping Sump / Trench Sensor(s ) . Model : 794380-208 ❑ Piping Sump / Trench Sensor(s) . Model : <br /> ® Fill Sump Sensor(s ) , Model : 794380-208 ❑ Fill Sump Sensor(s ) . Model : <br /> ❑ Mechanical Line Leak Detector. Model : <br /> ❑ Mechanical Line Leak Detector. Model : <br /> ® Electronic Line Leak Detector, Model : 8484 ❑ Electronic Line Leak Detector. Model : <br /> ® Tank Overfill / High -Level Sensor. Model: 847390- 109 W/Buzzer ❑ Tank Overfill / High- Level Sensor. Model : <br /> ❑ Other (specify equipment t e and model in Section E on Page 2 ), ❑ Other ( specify e ui ment type and model in Section E on Page 2) . <br /> Dispenser ID : 1 -2 Dispenser ID : 3-4 <br /> ® Dispenser Containment Sensor(s) . Model : 794380-208 ® Dispenser Containment Sensor( s) . Model : 794380-208 <br /> ® Shear Valve(s) . <br /> ® Shear Valve( s ) . <br /> ❑ Dispenser Containment Float(s) and Chain(s ) . ❑ Dispenser Containment Floats and Chain (s). <br /> Dispenser ID: 5-6 Dispenser ID : 7-8 <br /> ® Dispenser Containment Sensor(s ) . Model : 794380-208 ® Dispenser Containment Sensor(s) . Model : 794380-208 <br /> ® Shear Valve(s) . ® Shear Valve(s) . <br /> ❑ Dispenser Containment Floats and Chain (s). I ❑ Dispenser Containment Floats and Chain (s). <br /> Dispenser ID : 9- 10 Dispenser ID : 11 - 12 <br /> ® Dispenser Containment Sensor(s ) . Model : 7984380-208 2 Dispenser Containment Sensor(s) . Mode1794380-208 <br /> ® Shear Valve(s) . ® Shear Valve(s ) . <br /> ❑ Dispenser Containment Floats and Chains ! ❑ Dispenser Containment Floats and Chain (s), <br /> ' If the facility contains more tanks or dispensers , copy this form . Include information for every tank and dispenser at the facility. <br /> C . Certification - I certify that the equipment Identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines . Attached to this Certification is Information (e. g , manufacturers' checklists) necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports , I have also attached a <br /> copy of the report; (check all that apply) : ® System set-up Alarm history report <br /> Technician Name ( print) : Brian Roth Signature : <br /> Certification No . : A29956License , No. : 949066 <br /> Testing Company Name: Nucleus Pump Services Phone No . : (916 ) <br /> Testing Company Address : 601 First Ave . Sacramento Ca . Date of Testing/Servicing : <br /> Monitoring System Certification Page 1 of 4 12/07 <br /> 1 2/21 /07 <br />