Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax; (209)468-3433 Web:www.sjaov.orcI/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: I Facility Address: Date: <br /> VALLEY PACIFIC CHARTER WAY CARDLOCK 1501 W CHARTER WAY STOCKTON January 03 2019 <br /> Other Violations <br /> 2010 1 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> Current financial responsibility documents have not been submitted to the EHD. The most recent financial <br /> responsibility documents submitted in CERS are dated 2/14/17. Current financial responsibility documents are <br /> required to be submitted annually. Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov/, and upload the required documents. <br /> This is a minor violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. The map has not been updated to reflect the changes to <br /> the dispenser set up on site. A site plan must be submitted identifying the locations where monitoring will be <br /> performed. Immediately log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/ <br /> and upload a copy of the UST Monitoring Site Plan. <br /> This is a repeat violation, Class II. <br /> 201 CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br /> Maintenance and monitoring records for the last three years were not found on site. 2018 test results were not found <br /> on site, including monitoring system certification (1/17/18), secondary containment testing (1/17/18), and overfill <br /> prevention testing (10/26/18). These records shall be maintained on site for at least three years. Monitoring records <br /> include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; <br /> (3) results of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all <br /> readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) results of <br /> inventory readings and reconciliations. Immediately locate and maintain all maintenance and monitoring records for <br /> the last three years on site and submit copies to the EHD. <br /> This is a repeat violation, Class Il. <br /> 313 HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product-tight. <br /> Drips were observed in three separate locations under dispenser 5/6. All primary containment for the UST system <br /> must be tight. Immediately have a properly licensed, trained, and certified contractor repair or replace the failed <br /> component under permit and inspection of the EHD. <br /> This is a minor violation. <br /> FA0003976 PR0231989 SCO01 01/03/2019 <br /> EHD 23-01 Rev.09/22/16 Page 4 Of 5 Underground Storage Tank Program OIR <br />