r <br /> Franklin Fueling Systems <br /> EBW Phase I Equipment <br /> Required Inspection & Maintenance <br /> Spill Containers, Lids, and Drain Valves Fills Caps, Vapor & Delivery Elbows, & Vapor <br /> All styles of spill containers are to be visually inspected & Fill Adapters <br /> by the delivery operator prior to each delivery occurrence. The working seals and mating hardware surfaces on these <br /> The following is an inspection check list to follow: items are to be visually inspected by the delivery operator <br /> 1. Inspect the spill containment bucket for visible prior to each delivery occurrence. If visual seal wear or <br /> tank damage& perforation to the tank wall. If any tear is observed, replace immediately. It is recommended <br /> problems are observed, report them to the station that the station owner maintain a spare set of seals for <br /> operator. the fill &vapor caps on site. It is recommended that the <br /> 2. Inspect the spill containment equipment for the delivery service maintain a set of vapor and delivery elbow <br /> presence of any liquids or excessive foreign seals in the trailer equipment box. Damage to hardware <br /> materials (i.e. candy wrappers, rags, leaves, etc.) sealing surfaces will generally require that the item be <br /> and report to the station operator if liquids are replaced in it's entirety. Should this be observed, the <br /> present; remove any garbage prior to coupling to appropriate party needs to be informed so service can <br /> the fill adapter. be promptly scheduled. It is recommended that station <br /> owner/operators inspect their tank fill and vapor connection <br /> 3. Inspect the spill containment drain valve screen hardware at least once a month. <br /> (if applicable)for any foreign material. If any is <br /> present, remove it if possible. Report clogged Recommended Spare Parts & Part Numbers <br /> screens to the station operator. C.A.R.B. - EVR Approved <br /> 4. Inspect the spill containment lids or covers. Any 1. Vapor Caps-Aluminum body seal. <br /> noticeable lid damage needs to be immediately <br /> brought to the station operator's attention. If water 2. Product Caps- Nylon body seal. <br /> and/or fuels are observed in the spill containment, Not C.A.R.B. -EVR Approved <br /> immediately notify appropriate station personnel 1. Vapor Caps - Nylon body seal or(Chevron lip <br /> that the tank needs service. The presence of style) aluminum body seal . <br /> water indicates that either a lid/cover is not sealing 2. Product Caps-Nylon body seal Aluminum body <br /> properly or the tank walls have been perforated. seal. <br /> The presence of fuel may indicate a clogged drain <br /> valve screen. 3. EBW Product Elbow-880-450/455 (pull release) <br /> EBW recommends that the station owner/operator inspect body seal version (lever release) body seal <br /> version. <br /> their spill containment equipment at least once a month. <br /> This inspection should consist of the items listed both 4. EBW Vapor Elbow- Body seal. These products are <br /> above and below. not readily accessible for daily, weekly and monthly <br /> inspections. Prior to product deliveries, drop <br /> 1. Clean any foreign materials (i.e. dirt, sand, stone, tubes should be visually inspected for presence <br /> etc.)from the mating flanges for spill containment of a dipstick. Should a dipstick be left in a drop <br /> lids or covers.Any buildup of dirt will defeat the tube with an overfill valve, valve operation will be <br /> rainwater shedding provisions designed into the defeated. Leak integrity of these devices would be <br /> containment manhole lid/cover and will lead to evaluated during your tank tightness test. Should <br /> premature structural failure of the lid. a leak be observed, the leak path needs to be <br /> 2. Inspect the lid/cover seal (if applicable)for identified and addressed. In most cases, this leak <br /> damage. may be due to a damaged static seal. <br /> Recommended Spare Parts& Part Numbers Station Maintenance Logs <br /> 1. Replacement Drain Valve Kit-705-337-19("pull to EBW recommends that logs be maintained to record <br /> push" C.A.R.B. version). For other styles, please service and inspection frequency on all equipment. This <br /> consult Technical Support. is a good management tool that would identify suspect <br /> hardware if frequent repairs are logged. <br /> Page 1 of 2 <br />