My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHRISMAN
>
34243
>
2300 - Underground Storage Tank Program
>
PR0231801
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2020 12:35:19 PM
Creation date
9/15/2020 11:59:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231801
PE
2361
FACILITY_ID
FA0003290
FACILITY_NAME
COUNTRY MART GAS & FOOD
STREET_NUMBER
34243
Direction
S
STREET_NAME
CHRISMAN
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
25318004
CURRENT_STATUS
01
SITE_LOCATION
34243 S CHRISMAN RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN )O A Q U I N Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> COUNTRY MART GAS& FOOD 34243 S CHRISMAN RD, TRACY April 02,2019 <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms for the Diesel product, Diesel product#1,87 product and 91 product tank are not <br /> current in CERS. In the Diesel product, Diesel product#1, 87 product and 91 product tank states that vent piping <br /> has secondary containment to be fiberglass however single wall vent piping was observed while the inspector was <br /> out in the field. Furthermore the 87 product and 91 product vapor recovery piping was stated to be double wall <br /> however single wall piping was observed during the field inspection. Any change of information must be updated in <br /> CERS within 30 days of the changes. Immediately log into CERS, update the required information, and submit for <br /> review by the EHD. <br /> This is a repeat violation, Class II. <br /> 105 CCR 2632(d)(1),2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. In the Diesel#1 tank the monitoring plan states <br /> the mechanical leak detector model to be FE Petro however STPMLD model was observed during the field <br /> inspection. Furthermore the panel model listed in the monitoring plan is"TLS 350"however"TLS-350 Plus"was <br /> observed during the field inspection. The monitoring plan must be uploaded to the California Environmental <br /> Reporting System (CERS). Immediately log into CERS, make the necessary changes, and submit for review by the <br /> EHD. <br /> This is a repeat violation, Class II. <br /> 121 CCR 2712(f)Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 4/9/18 and an inspection report was issued identifying information to be submitted to <br /> bring this site into compliance. This information was required to be submitted by May 8th, 2018. This information <br /> was received on 5/31/18, 23 days late resulting in a non-compliant status for this facility. An operator that receives <br /> an inspection report shall have 30 days to submit a written response that includes a statement documenting <br /> corrective actions taken or proposing corrective actions which will be taken. Ensure that a written response <br /> documenting corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br /> This is a Class II violation. <br /> 124 CCR 2637.2(d&e), 2665(a&b)"Overfill Prevention Equipment Inspection Report Form"not submitted within 30 days <br /> of inspection. <br /> Overfill prevention equipment inspection report was performed on 1/30/19. A Overfill prevention equipment <br /> inspection report form has not been submitted to the EHD or the California Environmental Reporting System <br /> (CERS). A copy of the test report must be submitted within 30 days of the test. Immediately provide this report to <br /> the EHD. <br /> This is a minor violation. <br /> FA0003290 PR0231801 SCO01 04/02/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.