My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SAN JOAQUIN
>
345
>
2300 - Underground Storage Tank Program
>
PR0231867
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2020 12:56:14 PM
Creation date
9/15/2020 12:36:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231867
PE
2361
FACILITY_ID
FA0003959
FACILITY_NAME
AT&T CALIFORNIA - UE042
STREET_NUMBER
345
Direction
N
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
345 N SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9MMONJ ® TS - STS Sump Test System P9 , <br /> Franklin Fueling Systems <br /> Quick. Start Guide. <br /> TS - STS Overview TS - STS Installation <br /> The TS - STS system includes a TS - STS console within a convenient (D <br /> portable case , leak testing probes with 50 feet of cable , and probe 1 . ) Required Materials : <br /> hanging hardware (slip rings and chain ) . a . ) Tape to secure the probe cable b . ) Safety cones & signs <br /> After all fittings within the sump are sealed , the sump is filled with a <br /> water- based test solution that covers all sump penetration holes . The c . ) Grounded , 3 - pronged extension cord <br /> probe is installed so the float is floating on the surface of the test solution . d . ) Flat pieces of metal to suspend leak testing probe over sumps <br /> The TS - STS console is quickly programmed with the site name and 2 . ) Work safely — install Safety Cones and Signs at the site <br /> address , number of sumps , the 7- digit code- names for each sump , and <br /> the correct Time/Day/Date before leak testing . 3 . ) The probes are precision instruments — handle with care ! <br /> Pressing the Test key at the console keypad starts sump leak tests for 4 . ) The STS probes are shipped with cables attached , do not remove <br /> all sumps . The test time is 15 minutes and tests for a level change the cable from the probe end . . . remove at the console case only . <br /> greater than 0 . 002 inches . If the level of a sump drops more than the 5 . ) Inspect probes for proper float movement before use , then install <br /> leak limit during the test , the Sump Leak Test Report will show a fail probes as shown in Section 1 <br /> result when the test is finished . Leak tests can also be programmed <br /> (scheduled ) to start at desired times . 6 . ) Connect the yellow probe cables to the receptacles at the TS - STS <br /> When finished , leak test reports will automatically print out at the console case . Make sure to line up keyways before inserting cable and <br /> printer . Extra copies of this report can be printed using the report key . A tightening the screw-on connector. <br /> newly completed Sump Leak Test will overwrite the previous results 7 . ) Locate the TS - STS case outside of the Hazardous Area and tape <br /> stored in memory . Save sump leak test reports and provide copies as the cable down to prevent probe movement during the test and to <br /> evidence of compliance with regulations . reduce tripping hazards <br /> Recommendation : Use a computer and the Tech version of 8 . ) Setup / Program the TS -STS console per Section 2 <br /> System Sentinel '"' to record site data, sump code-names, and test <br /> I esults. Test results can also be extracted from Comm Port 1 at 9 ) Start sump leak test( S) On sumps that are ready <br /> NoTf the bottom of the TS-STS console (also see Section 4). 10 . ) Always clean , dry, and store probes in the probe carrying case after <br /> Reference Federal and State regulations for leak limit and test each use <br /> time requirements. Recommendations for locating the TS-STS <br /> console outside of the (Class 1 , Division 1, Group D) Hazardous Areas 11 • ) Test each of the probes on a monthly basis to ensure its ability to <br /> during testing, are based on NFPA 30, NEPA 30A and NEPA 70 (NEC). detect leaks . Install the probe in a test container and initiate a test . <br /> After 5 minutes , remove about 0 . 12 inches of water. When the test <br /> INCON P/N000-3004RevD Feb. 2009 © www .fraklinfuelino.com completes , the test report should show a Failed result if the probe <br /> This document may change without prior notice. INCOW is a Registered Trademark of Franklin Fueling Systems <br /> is working properly. <br />