Laserfiche WebLink
CON ® TS - STS Sump Test System Pg ' <br /> Franklin Fueling Systems <br /> _ Quick Start Guide <br /> TS - STS Overview 'I TS - STS Installation <br /> The TS -STS system includes a TS -STS console within a convenient <br /> portable case , leak testing probes with 50 feet of cable , and probe 1 . ) Required Materials : <br /> hanging hardware (slip rings and chain ) . <br /> a . ) Tape to secure the probe cable b . ) Safety cones & signs <br /> After all fittings within the sump are sealed , the sump is filled with a <br /> water- based test solution that covers all sump penetration holes . The c . ) Grounded , 3 - pronged extension cord <br /> probe is installed so the float is floating on the surface of the test solution . d . ) Flat pieces of metal to suspend leak testing probe over sumps <br /> The TS- STS console is quickly programmed with the site name and 2 . ) Work safely — install Safety Cones and Signs at the site <br /> address , number of sumps , the 7 - digit code- names for each sump , and <br /> the correct Time/Day/Date before leak testing . 3 . ) The probes are precision instruments — handle with care ! <br /> Pressing the Test key at the console keypad starts sump leak tests for 4 . ) The STS probes are shipped with cables attached , do not remove <br /> all sumps . The test time is 15 minutes and tests for a level change the cable from the probe end . . . remove at the console case only . <br /> greater than 0 . 002 inches . If the level of a sump drops more than the 5 . ) Inspect probes for proper float movement before use , then install <br /> leak limit during the test , the Sump Leak Test Report will show a fail probes as shown in Section 1 <br /> result when the test is finished . Leak tests can also be programmed <br /> (scheduled ) to start at desired times . 6 . ) Connect the yellow probe cables to the receptacles at the TS -STS <br /> When finished , leak test reports will automatically print out at the console case . Make sure to line up keyways before inserting cable and <br /> printer . Extra copies of this report can be printed using the report key . A <br /> tightening the screw-on connector. <br /> newly completed Sump Leak Test will overwrite the previous results 7 . ) Locate the TS - STS case outside of the Hazardous Area and tape <br /> stored in memory . Save sump leak test reports and provide copies as the cable down to prevent probe movement during the test and to <br /> evidence of compliance with regulations . reduce tripping hazards <br /> Recommendation : Use a computer and the Tech version of 8 . ) Setup / Program the TS - STS console per Section 2 <br /> System Sentinel TM to record site data, sump code-names, and test <br /> results. Test results can also be extracted from Comm Port 1 at 9 • ) Start sump leak test (s) on sumps that are ready <br /> t4oTf <br /> the bottom of the TS -STS console (also see Section 4). 10 . ) Always clean , dry, and store probes in the probe carrying case after <br /> Reference Federal and State regulations for leak limit and test each use <br /> time requirements. Recommendations for locating the TS-STS <br /> console outside of the (Class I , Division 1, Group D) Hazardous Areas 11 . ) Test each of the probes on a monthly basis to ensure its ability to <br /> during testing, are based on NFPA 30, NFPA 30A and NFPA 70 (NEC). detect leaks . Install the probe In a test container and initiate a test . <br /> After 5 minutes , remove about 0 . 12 inches of water. When the test <br /> INCON P/N 000-3004Rev.D Feb. 2009 O www .fraklinfuelinp .com completes , the test report should show a Failed result if the probe <br /> This document may change without prior notice. INCON ' is a Registered Trademark of Franklin Fueling Systems <br /> is working properly. <br />