My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2020 3:20:22 PM
Creation date
9/15/2020 1:46:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UG010 <br /> UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM (Page I of 6) <br /> Type of Action ❑Installation Test ❑x Repair Test ❑Six Month Test ❑36 Month Test <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10181541 10/29/2019 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Pacific Bell Telephone Co. dba AT&T California <br /> Business Site Address City ZIP Code <br /> 1812 Coley Ave. I Escalon 95320 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test(Print as shown on the ICC Certification) Phone# <br /> Gage Hart (714)560-8222 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 588098 8361014 5/6/2021 <br /> M. SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID: (By tank number,stored product,etc.) A UG01 00001 B C D <br /> Tank Containment <br /> Tightness Test Result ❑Pass ❑Fail O NA ❑Pass ❑Fail ❑NA ❑Pass ❑ Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Product Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail Z NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail Z NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail Z NA ❑ Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail Z NA ❑Pass ❑ Fail ❑NA ❑Pass ❑Fail ❑ NA ❑Pass ❑Fail ❑NA <br /> Vent Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail Z NA ❑Pass ❑ Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail Z NA ❑Pass ❑ Fail ❑NA ❑Pass ❑Fail ❑ NA ❑Pass ❑Fail ❑NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail Z NA ❑Pass ❑ Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail Z NA ❑Pass ❑ Fail ❑NA ❑Pass ❑Fail ❑ NA ❑Pass ❑Fail ❑NA <br /> Turbine/Product Piping Sump <br /> Tightness Test Result Z Pass ❑Fail ❑NA ❑Pass ❑ Fail ❑NA ❑Pass ❑Fail ❑ NA ❑Pass ❑Fail ❑NA <br /> Fill Riser Sump <br /> Tightness Test Result ❑Pass ❑Fail Z NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑ NA ❑Pass ❑Fail ❑NA <br /> VENT/TRANSITION SUMP ID: a lb C d <br /> Tightness Test Result ❑Pass ❑Fail Z NA ❑Pass ❑ Fail ❑NA ❑Pass ❑Fail ❑ NA ❑Pass ❑Fail ❑NA <br /> UDC ID: 1 2 3 4 <br /> Tightness Test Result ❑Pass ❑Fail Z NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> UDC ID: 5 6 7 8 <br /> Tightness Test Result ❑Pass ❑Fail Z NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> UDC ID: 9 10 11 12 <br /> Tightness Test Result ❑Pass ❑Fail Z NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> All items marked"Fail"or"NA"must be explained in their respective"COMMENTS"section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the secondary containment was tested in accordance with California Code of Regulations,Title 23,Division <br /> 3,Chapter 16, Section 2637 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> 67-ae_ ❑ Check If Action Item(s)Are Present <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,NA=Not Applicable,UDC=Under- <br /> Dispenser Containment <br />
The URL can be used to link to this page
Your browser does not support the video tag.