Laserfiche WebLink
<br /> <br /> UST Spill Bucket <br /> Integrity Testing Form <br />Underground Storage Tanks (UST) Program <br /> <br />Instructions on Page 3 <br />Purpose: This procedure is to test the leak integrity of single- and double-walled spill buckets. See reverse <br />side for basic hydrostatic testing instructions. Consult PEI/RP1200, Section 6.2 for hydrostatic test method, <br />Section 6.3 for single-walled vacuum test method, and Section 6.4 for double-walled vacuum test method. <br />Testing Information <br />1. Tank number 87 Waste Oil <br />2. Product stored Unleaded Waste Oil <br />3. Spill bucket capacity 5 Gallons 5 Gallons <br />4. Manufacturer OPW OPW <br />5. Construction <br /> Single-walled <br /> Double-walled <br /> Single-walled <br /> Double-walled <br /> Single-walled <br /> Double-walled <br /> Single-walled <br /> Double-walled <br /> Single-walled <br /> Double-walled <br /> Single-walled <br /> Double-walled <br />6. Test type <br /> Hydrostatic <br /> Vacuum <br /> Single-walled <br /> Double-walled <br /> Hydrostatic <br /> Vacuum <br /> Single-walled <br /> Double-walled <br /> Hydrostatic <br /> Vacuum <br /> Single-walled <br /> Double-walled <br /> Hydrostatic <br /> Vacuum <br /> Single-walled <br /> Double-walled <br /> Hydrostatic <br /> Vacuum <br /> Single-walled <br /> Double-walled <br /> Hydrostatic <br /> Vacuum <br /> Single-walled <br /> Double-walled <br />7. Spill bucket type <br /> Product <br /> Vapor <br /> Product <br /> Vapor <br /> Product <br /> Vapor <br /> Product <br /> Vapor <br /> Product <br /> Vapor <br /> Product <br /> Vapor <br />8. Liquid and debris <br />removed from spill <br />bucket:* Yes No Yes No Yes No Yes No Yes No Yes No <br />9. Visual inspection <br />(No cracks, loose parts or <br />separation of the bucket <br />from the fill pipe.)? Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail <br />10. Tank riser cap included in <br />test? Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA <br />11. Is drain valve included in <br />test? Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA Yes No NA <br />12. Starting level 13.25” 13.50” <br />13. Test start time 9:05 am 9:05 am <br />14. Ending level 13.25” 13.50” <br />15. Test end time 10:05 am 10:05 am <br />16. Test period 1 hour 1 hour <br />16. Level change 0 0 <br />Test results: Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail <br />Pass/fail criteria: Must pass visual inspection. Hydrostatic: Water level drop of less than 1/8 inch; Vacuum single-walled <br />only; Maintain at least 26 inches water column; Vacuum double-walled; maintain at least 12 inches water column. <br />Comments: <br /> <br />* All liquids and debris must be disposed of properly. <br />Testing company <br />name: CGRS Inc Tester’s name: Garrett Warren <br /> Date: 12-4-19 Tester’s signature: <br /> <br /> <br /> <br /> <br /> <br />