My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
1403
>
2300 - Underground Storage Tank Program
>
PR0231995
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2024 2:28:48 PM
Creation date
9/15/2020 3:58:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231995
PE
2361 - UST FACILITY
FACILITY_ID
FA0006438
FACILITY_NAME
United # 5446
STREET_NUMBER
1403
Direction
W
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12323246
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
1403 W COUNTRY CLUB BLVD STOCKTON 95204
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
140
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ 0 A U I Environmental Health Department <br /> OUNT <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> United #5446 1 1403 W COUNTRY CLUB BLVD, STOCKTON May 22, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 319 CCR 2635, 2637.1, 2665, 2712 No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be <br /> tested. <br /> The used oil spill container failed when tested. All spill containers shall have a minimum capacity of five gallons and <br /> be capable of containing a spill or overfill until it is detected or cleaned up. Immediately contact a properly licensed, <br /> trained, and certified contractor to repair or replace the spill container under permit and inspection of the EHD. <br /> The used oil UST is not equipped with a spill container at the point of input. All USTs shall be equipped with a spill <br /> container that collects any hazardous substances spilled during product delivery operations, has a minimum <br /> capacity of five gallons and a drain valve that allows drainage of the collected spill into the primary container or <br /> provide a means to keep the container empty. Immediately contact a properly licensed, trained, and certified <br /> contractor to install an approved spill container under permit and inspection of the EHD. If a spill container can't be <br /> installed immediately, there is a possibility that the used oil UST system may be red tagged to prevent inputs. <br /> This is a repeat violation, Class II. <br /> 320 CCR 2635, 2637.2, 2665, 2712 Failure to comply with the installation, inspection, or record keeping of the overfill <br /> prevention. <br /> Overfill prevention testing has not been conducted. This testing was required to be conducted by October 13, 2018. <br /> Immediately schedule this testing and provide 48 hours notification to the EHD. Ensure all future testing is <br /> conducted within required time frames. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> The monitoring system certification was conducted today, on 5/22/2019 and was not fully witnessed by EHD. <br /> Looked inside all sumps and UDCs. Verified sensor locations and piping communication. Verified spill bucket 5 <br /> gallon capacity. Paperwork inspection was completed on 6/7/2019. A complete report was provided at that time. <br /> An inspection checklist was provided to the facility operator on the day of inspection. The EHD has written the <br /> complete report which replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> Documents provided: Return to Compliance Certification form, schedule of free CUPA classes <br /> FA0006438 PR0231995 SCO01 05/22/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 6 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.