My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MYRTLE
>
2849
>
2300 - Underground Storage Tank Program
>
PR0538822
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 9:09:31 AM
Creation date
9/16/2020 10:44:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0538822
PE
2351
FACILITY_ID
FA0022301
FACILITY_NAME
Regional Transportation Center
STREET_NUMBER
2849
Direction
E
STREET_NAME
MYRTLE
STREET_TYPE
St
City
Stockton
Zip
95205
APN
157-020-11
CURRENT_STATUS
01
SITE_LOCATION
2849 E Myrtle St
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J OAQ U I N Environmental Health Department <br /> COUNTY Kasey Foley , REHS , Interim Director <br /> cq` ' a �P Greatness rows here . PROGRAM COORDINATORS <br /> F° 9 Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> December 26 , 2019 <br /> Joseph Bagley <br /> Bagley Enterprises <br /> 2370 Maggio Cir . #4 <br /> Lodi , CA 95240 <br /> Re : Regional Transportation Center SR0081459 <br /> 2849 E . Myrtle St . , Stockton , CA 95205 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to repair the diesel leak inside the transition sump in the filter room on the <br /> underground storage tank ( UST) system at the above noted address . The permit has been approved <br /> with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust (.a'� sl4ov . om to arrange the following inspection appointments <br /> ( a 48- hour notice is required for inspection appointments ) . Please be aware that inspections <br /> for emergency work must be scheduled within five days of permit approval . <br /> a . Primary piping soap test : One hour pneumatic pressure test at 110 % of operating pressure , <br /> or 40 psi , whichever is greater, of both diesel piping lines . <br /> b . Secondary piping soap test : One hour pressure test per manufacturer' s guidelines , of both <br /> diesel piping lines . If there are no manufacturer' s guidelines , test shall be performed using <br /> an applicable method specified in an industry code or engineering standard . <br /> c . Verification of Secondary piping slope , at 1 /8 inch per foot or greater, to a containment sump <br /> with an audible/visual alarm . <br /> d . Verification of all pipe setbacks and burial depth according to the manufacturer' s installation <br /> instructions . Verification of appropriate backfill . <br /> e . Integrity testing of the diesel transition sump per the manufacturer' s installation instructions <br /> prior to backfill , and brine type verification and brine addition prior to backfill . <br /> f. Sampling under any removed piping and/or sumps . <br /> g . Verification of brine communication in the diesel transition sump . <br /> h . Verification of continuous monitoring on both diesel piping lines and the diesel transition <br /> sump , once concrete is poured in accordance with the manufacturer' s guidelines . <br /> i . Primary piping test : Witness tightness test performed by SWRCB licensed tank tester or <br /> receive passing 0 . 1 gallon per hour test results from the PLLD ( if installed ) , of both diesel <br /> piping lines . A visual inspection is required for PLLD tested lines . <br /> j . If concrete will be broken near the tanks or sumps , a secondary containment test must be <br /> performed on the affected components once concrete is poured , in accordance with the <br /> manufacturer' s guidelines . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468-3420 F 209 464 -0138 1 www . sjgov . org/ehd <br />
The URL can be used to link to this page
Your browser does not support the video tag.