Laserfiche WebLink
UL/ ULC Listed Red Thread ® 11A Piping System <br /> Lowest Total Cost Ownershipt <br /> Benefits of [ Material Cost + Installation Cost] - System Life <br /> Maintenance cost and replacement cost not required with RED THREAD IIA piping system . <br /> Fiberglass Piping 4:OLUnderwriter ' s <br /> h i rty Ye a r Outstanding Corrosion <br /> in Underground W a r r a n t y * Resistance — RED THREAD IIA <br /> With over 4. 0 piping systems resist internal and <br /> Fuel Applications years proven external corrosion from hazardous <br /> performance in soils , fuels and other corrosive <br /> TIME TESTED the marketplace , fluids . <br /> • 30 -Year Warranty Laboratories , Inc . • Quality Assurance — RED <br /> and Underwriter ' s Laboratories THREAD IIA quality assurance <br /> • Installed since 1964 Canada ( UL / ULC ) Listed RED procedures meet or exceed the <br /> THREAD IIA pipe , fittings and test requirements of UL/ ULC . <br /> adhesive carry a 30 -year warranty. <br /> • Never been removed due The product is warranted to be Permeability — RED THREAD <br /> to fuel incompatibility free from defects in material and IIA permeability resistance <br /> workmanship —and against internal greatly exceeds UL allowable <br /> • Total immersion testing and external corrosion —when used permeability. <br /> in fuels for underground transportation of <br /> 2004 UL 971 <br /> fuels . : <br /> Primary - 1 gm /m2/day <br /> • Case History G7301 Leak Prevention Sump <br /> ( 0 . 053 gal / 100 ft . of 2 " pipe , <br /> — <br /> entry/ termination fittings provide 30 days ) <br /> positive seal at the sump to help Secondary - 4 gm / m2/day <br /> LOWEST TOTAL COST prevent leaking of underground ( 0 . 213 gal / 100 ft . of 2 " pipe , <br /> OF OWNERSHIP fuel in or out of the sump . This 30 days ) <br /> fitting also helps provide Class 1995 UL 971 : <br /> • No reinstall costs due I ( leak prevention ) protection Primary - 4 gm /m2/day <br /> which complies with California ' s ( 0 . 213 gal / 100 ft . of 2 " pipe , <br /> to fuel incompatibility p <br /> requirement for continuous 30 days ) <br /> interstitial monitoring of the piping Secondary - 24 gm / m2/day <br /> • Homogenous system : no ( 1 . 278 gal / 100 ft . of 2 " pipe , <br /> liner, no bladder system ' s secondary containment . <br /> 30 days ) <br /> E x c e p t 1 o n a I F10VIV <br /> A TRUE PIPE IN A PIPE Characteristics - Two - inch <br /> RED THREAD IIA pipe has the <br /> ® Interstitial space largest I . D . ( 2 . 235 " ) in the fueling <br /> communication industry—allowing you to sell twice <br /> the fuel per foot than any 11 / 2 <br /> • Leak prevention , not flexible product on the market . <br /> leak detection Three - inch RED THREAD IIA <br /> fiberglass pipe has a nominal 3 . 36 ®Id vs New - Pipe in the foreground was <br /> installed in 1973 and removed 27 years <br /> INSTALL IT BURY IT, I . D . ; four- inch pipe has a 4 . 36 I . D . later when the station closed. <br /> • <br /> FORGET IT! <br /> * Please review Fiber Glass Systems ' written warranty to determine the terms and conditions . <br />