My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MYRTLE
>
2849
>
2300 - Underground Storage Tank Program
>
PR0538822
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 9:09:31 AM
Creation date
9/16/2020 10:44:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0538822
PE
2351
FACILITY_ID
FA0022301
FACILITY_NAME
Regional Transportation Center
STREET_NUMBER
2849
Direction
E
STREET_NAME
MYRTLE
STREET_TYPE
St
City
Stockton
Zip
95205
APN
157-020-11
CURRENT_STATUS
01
SITE_LOCATION
2849 E Myrtle St
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UL/ ULC Listed Red Thread ® IIA Piping System <br /> RED THREAD IIA PIPING RED THREAD IIA <br /> RED THREAD IIA Primary Piping Secondary Containment Piping <br /> Nom . Pipe Size Part Number Pipe Length Nom . Pipe Size Part Number Pipe Length <br /> ( In . ) mm (ft • ) ( In . ) mm (ft . ) <br /> 2 50 011020-069- 1 15 3 80 011030-0694 15 <br /> 2 50 011020-069-2 22-25 3 80 011030-069- 5 22-25 <br /> 2 50 011020-069- 3 26-30 3 80 011030-069-6 26-30 <br /> 3 80 011030-069- 1 15 4 100 011040 -077- 5 15 <br /> 3 80 011030-069-2 22-25 4 100 011040-069-5 22-25 <br /> 3 80 011030 -069- 3 26-30 4 100 011040-077-6 26-30 <br /> 4 100 011040-071 - 1 15 6 150 011060- 120 -5 15 <br /> 4 100 011040-069-2 22-25 6 150 011060 - 1204 22-25 <br /> 4 100 011040-071 -3 26-30 6 150 011060 - 120-6 26- 30 <br /> DIMENSIONAL DATA <br /> Nominal Nominal External Pressure <br /> PiNominal Nominal Wall Nominal Pressure/ Mill Test Max . Rating <br /> Pipe I . D . O . D . Weight Temperature Pressure <br /> Size ( In ./ Thickness ( psig/MPa ) <br /> mm ) ( In ./mm ) ( In ./mm ) (In . /aim ) ( lbs ./ftdkg �m ) Max . Rating ( psig/ MPa) 75° F/240C 150° F/660C <br /> 2 1 2 . 235 2 . 375 . 070 0 . 5 250 psig @ 150 ° F 375 85 80 <br /> 50 57 61 1 . 78 0 . 74 1 . 72 MPa @ 66 ° C 2 . 59 . 57 . 55 <br /> 3 3 . 360 3 . 500 . 070 0 . 7 175 psig @ 150 ° F 300 36 34 <br /> 80 F� 5 50 1 . 0 / -1 . 21 Mra CO) 66 ° C 2 . 07 . 25 . 23 <br /> 4 4 . 360 4 . 560 . 085 1 . 2 125 psig @ 150 ° F 265 34 30 <br /> 100 111 116 2 . 16 1 . 79 0 . 86 MPa @ 66 ° C 1 . 83 . 23 . 21 <br /> 6 6 .408 6 . 678 . 135 2 . 4 20 psig @ 150 ° F 265 22 20 <br /> 150 163 170 3 . 43 3 . 51 0114 @ 66 ° C 1 . 83 . 15 . 14 <br /> RED THREAD IIA Pipe Bending Radius , Minimum <br /> PROPERTY psi @ 75°F MPa @ 24°C oi000iipsi @ 150 ° F MPa @ 66° C Nominal <br /> Axial Tensile (ASTM D2105 ) Pipe Size 2 " 3 " 4" 6" <br /> Ultimate Stress 10 , 300 71 . 0 8 , 200 56 . 5 ( inches) <br /> Design Stress 21575 17 . 8 21050 14 . 1 Ft . 75 110 140 204 <br /> Modulus of Elasticity 1 . 82 x 106 12548 1 .42 x 106 979121 . 3 33 . 5 42 . 7 62 . 2 <br /> m <br /> Axial Compression (ASTM D695 ) ( 1 ) All values except pressure -temperature <br /> Ultimate Stress 33 , 300 230 . 0 25 , 600 177 . 0 maximum rating are nominal values. Tolerances <br /> Design Stress 81300 57 . 2 61400 44 . 1 or maximum/minimum limits can be obtained <br /> Modulus of Elasticity 1 . 26 x 106 8687 . 89 x 106 6136 from Smith Fibercast. <br /> (2 ) All sizes can accept full vacuum pressures <br /> Beam Bending (SFPTM ) at maximum temperature ratings. <br /> Ultimate Stress 23 , 000 159 . 0 19 , 200 132 . 0 (3) Ultimate and allowable design stresses are <br /> Design Stress (4) 2 , 900 20 . 0 21400 16 . 5 based on minimum reinforced wall thickness . <br /> Pipe is manufactured in compliance with ASTM <br /> Modulus of Elasticity 2 . 18 x 106 15031 1 . 70 x 106 11721 D2996. <br /> ( Long Term per ASTM D2925 ) (4 ) Design bending stress is 1 /8 of ultimate to <br /> Hydrostatic Burst (ASTM D1599 ) account for combined stress (i . e . bending and <br /> pressure) , <br /> Ultimate Hoop (5) Design stress is based on long term cyclic <br /> Tensile Stress 34 , 000 234 39 , 200 271 fatigue data using ASTM D2992 test method . <br /> Hydrostatic Design (ASTM D2992 ) 2 "-3 " 2 " & 3" 2 " & 3" 2 " & 3 " However, all testing is not complete at time of <br /> printing. <br /> Procedure A 9 ,410(5) 64 . 9(5 ) 7 , 400 (7 ) 51 (6 ) (6) For RED THREAD IIA pipe the hydrostatic <br /> Cyclic 150 X 106 4"-6" 4" 6" 4"-6" 4 "-6" cyclic design stress was determined at 150° and <br /> Cycles 13 , 040(6) 89 . 9 (6 ) 10 , 450 72 . 1 200° F, per ASTM D2992 Procedure A. Based <br /> on this data , the extrapolated value at 75° F is <br /> Coefficient of Linear 0 . 88 x 10-5 in ./in . /° F 13, 030 psi. <br /> Thermal Expansion (SFPTM ) 1 . 58 x 10'Fnim/mm/° C ( 7 ) For RED THREAD IIA pipe the hydrostatic <br /> Specific Gravity 1 8 cyclic design stress was determined at 750 and <br /> p y 2007, per ASTM D2992 Procedure A. Based <br /> Flow Factor on this data , the extrapolated value at 150° F is <br /> Hazen-Williams Coefficient 150 7 ,400 psi . <br /> 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.