Laserfiche WebLink
S0 JOA U 1 Environmental Health Department <br /> U ;� i I <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> STOCKTON AUTO CENTER CAR WASH 3434 E HAMMER LN, STOCKTON November 22, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 319 CCR 2635, 2637.1,2665, 2712 No spill bucket,failed to contain 5 gallons, no means to keep it empty, or failed to be <br /> tested. <br /> OBSERVATION: The diesel spill container failed when tested. <br /> REGULATION GUIDANCE:All spill containers shall have a minimum capacity of five gallons and be capable of <br /> containing a spill or overfill until it is detected or cleaned up. <br /> CORRECTIVE ACTION: Immediately contact a properly licensed,trained, and certified contractor to repair or <br /> replace the spill container under permit and inspection of the EHD. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> The annual monitoring system certification and leak detector testing were performed on 11/5/2019 but spill <br /> container testing was not completed. On site at 12:30pm to witness a routine spill container test on the 87, 91, <br /> and diesel tank. Service technician Ed Stearns stated that they were having trouble removing the 87 spill <br /> container and that he will start the test for this container at a later time. The start time for the diesel and 91 <br /> product spill container was at 12:58pm. The start time for the 87 spill container was at 1:28pm. All passed <br /> except the diesel spill container. The diesel spill container failed when tested. <br /> Note: Immediately submit proof of current spill container certification for Ed Stearns to the EHD. If this <br /> certification is not submitted to EHD or the technician does not have the current certification the spill container <br /> tests will need to be re conducted by a properly certified technician or EHD staff time associated with a re <br /> inspection will be billed at a current hourly rate ($152). <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: November 22, 2019 Inspector: Inspector Phone: <br /> Printed Name and Title: SHEWIT WOLDEAREGAY, EH Specialist (209)468-0216 <br /> Josh Karpinski, Manager <br /> FA0003681 PR0232398 SCO02 11/22/2019 <br /> EHD 23-01 Rev.9/20/2019 Page 4 of 4 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />