6 ' -4000 DWT6 Double -Wall Tank <br /> 3958 Gals <br /> DIPSTICK GALLONS DIPSTICK GALLONS <br /> 60 1 /8 3559 66 118 3823 <br /> 60 1 /4 3565 66 1 /4 3827 <br /> 60 3/8 3571 66 3/8 3832 <br /> 60 1 /2 3577 66 1 /2 3836 <br /> 60 5/8 3584 66 5/8 3840 <br /> 60 3/4 3590 66 3/4 3845 CONTAINMENT <br /> 60 7/8 3596 66 7/8 3849 S O L 1.1 T I O N So <br /> 61 3602 67 3853 <br /> 61 1 /8 3608 67 1 /8 3857 HOW TO PROPERLY GAUGE YOUR TANK : <br /> 61 1 /4 3614 67 1 /4 3861 Underground storage tanks require periodic measurement to determine current <br /> 61 3/8 3620 67 3/8 3865 inventory level. Using the proper methods when gauging your tank's contents will <br /> insure the most accurate reading and insure that you do not damage your tank . The <br /> 61 1 /2 3626 67 1 /2 3869 following procedure should be followed whenever you use a gauge stick to determine <br /> 61 5/8 3632 67 5/8 3873 the amount of product that is in your tank : <br /> 61 3/4 3638 67 3/4 3877 1 ) Use a wood dipstick with a rubber or nylon tip . Metallic dipsticks are not <br /> 61 7/8 3644 67 7/8 3881 recommended . This will insure that frequent tank gaugings or an accidental dropping <br /> of the gauge stick into the tank will not damage the tank bottom . <br /> 62 3650 68 3885 2 ) Slowly lower your gauge stick into the fill port until it touches the tank bottom . <br /> 62 1 /8 3656 68 1 /8 3888 Never free drop the gauge stick . This can result in inaccurate measurements due to <br /> 62 1 /4 3662 68 1 /4 3892 product splashing . Free dropping can also result in gauge stick damage and tank <br /> damage . <br /> 62 3/8 3668 68 3/8 3896 3 ) Remove your dipstick slowly and read the product level directly from the gauge <br /> 62 1 /2 3673 68 1 /2 3899 stick . <br /> 62 5/8 3679 68 5/8 3903 Water Paste Detection <br /> 62 3/4 1 3685 68 3/4 1 3906 To detect water in the tank bottom , water detection paste is available from petroleum <br /> 62 7/8 3690 68 7/8 1 3909 equipment distributors. However, some water detection paste cannot detect antifreeze <br /> 63 3696 69 3912 mixtures . If antifreeze mixtures are used for the cavity monitoring fluid , the following <br /> 63 1 /8 3701 69 1 /8 3915 product is capable of detecting water or antifreeze (brine or up to 50 percent glycol) <br /> solution in the tank water bottoms : <br /> 63 1 /4 3707 69 1 /4 3919 WATER FINDER #7686- 1870 <br /> 63 3/8 3712 69 3/8 3922 DAYCO/NATIONAL <br /> 63 1 /2 3718 69 1 /2 3924 DAYTON , OH <br /> TEL: 1 -800-283-2926 <br /> 63 5/8 3723 69 5/8 3927 FAX: 1 -800-688-4854 <br /> 63 3/4 3729 69 3/4 3930 <br /> 63 7/8 3734 69 7/8 3933 Caution <br /> 64 3739 70 3935 Pressurized deliveries are not recommended . If the delivery vehicle uses pumps to fill <br /> the tank , install overfill shutoff equipment in the tank and truck to prevent the tank from <br /> 64 1 /8 3745 70 1 /8 3938 being overfilled . Overfilling the tank under pressure will damage the tank even if <br /> 64 1 /4 3750 70 1 /4 3940 the tank vent is unrestricted . <br /> 64 3/8 3755 70 3/8 3942 Containment Solutions , Inc . <br /> 64 1 /2 3760 70 1 /2 3945 5150 Jefferson Chemical Road <br /> 64 5/8 3765 70 5/8 3947 Conroe , TX 77301 <br /> 64 3/4 3770 70 3/4 3949 Tel : 936 =756 =7731 <br /> 64 7/8 3775 70 7/8 3950 Fax: 936=756m7766 <br /> 65 3780 71 3952 Note : Calibration chart is based on the fluid level above a 5/16 " deflector plate . <br /> 65 1 /8 3785 71 1 /8 3954 <br /> 65 1 /4 3790 71 1 /4 3955 <br /> 65 3/8 3795 71 3/8 3956 <br /> 65 1 /2 3800 71 1 /2 3957 <br /> 65 5/8 3804 71 5/8 3958 <br /> 65 3/4 3809 <br /> 65 7/8 3814 <br /> 66 3818 <br /> Containment Solutions, Inc. 3 <br />