My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0013627
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CARPENTER
>
2482
>
2600 - Land Use Program
>
PA-1900132
>
SU0013627
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/25/2022 11:52:58 AM
Creation date
9/17/2020 1:47:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0013627
PE
2631
FACILITY_NAME
PA-1900132
STREET_NUMBER
2482
Direction
E
STREET_NAME
CARPENTER
STREET_TYPE
RD
City
STOCKTON
Zip
95205-
APN
17914018
ENTERED_DATE
9/15/2020 12:00:00 AM
SITE_LOCATION
2482 E CARPENTER RD
RECEIVED_DATE
5/2/2022 12:00:00 AM
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� s N <br /> 3 4 5 �.. <br /> Received By <br /> CARPENTER OF RD ��-� 208.7' 1 20' PROJECT DEDICATED GENERAL NOTES: �' On <br /> -� 1 ACCESS ROAD. FIRST a1 <br /> 1 _- 2oe�o 100'ASPHALT 1 . PROJECT ADDRESS: SOUTHERN 2 ACRE PORTION OF THE PROPERTY AT <br /> � <br /> 20' MIN ACCESS ���� <br /> 11 ROAD FROM _ - ' - N�1° 4 �� 2482 CARPENTER RD, STOCKTON, CA 95205 <br /> 1 CARPENTER 51) -- 2. ASSESSOR PARCEL NUMBER: "179-140-180-000 <br /> EXISTING WASTEWATER <br /> 38 EXISTING 1 SEPTIC AND LEECH LINES 3. FIRE ACCESS: 20 FOOT MINIMUM ACCESS ROAD FROM CARPENTER ROAD. <br /> 1 <br /> THIS TOPOGRAPHIC SURVEY WAS PERFORMED OY SPIRO LAND -_-- �- BUILDING 1 01 4. ENEL WILL WORK WITH SAN JOAQUIN COUNTY AND THE SELECTED <br /> 1 SURVEYING INC. ON JULY I3, 1¢AND 15, 2OT9. APPRO}C ��'� 1 <br /> MONUMENTS ON rROL WAS <br /> Sr DL AND EEDS.E TERL(NG _--- - B,2a0 S❑ FT BATTERY VENDOR ON AN APPROPRIATE FIRE SUPPRESSION SYSTEM <br /> 11 1 <br /> SHOULD NOT O SE USED FOR "MApplR CITY aPURPOSES RTICAL �-�- ��� --- "° 1 EXISTING 01 AND DEFLAGRATION ENCLOSURE DESIGN PRIOR TO SUBMITTING THE <br /> A 1 1 BENCHMARK M6, ELEVATION 25.32'NAM 1 WATER WELL <br /> 1 � --l_- -_--- 6� 1 BUILDING PERMIT. <br /> _-fir r 5. A WATER SUPPLY AS REQUIRED BY THE LOCAL FIRE OFFICIAL WILL BE <br /> PROVIDED. <br /> 5. AREA OF WORK DOES NOT AFFECT THE WHOLE PARCEL. <br /> 1 1 - 7. NO WATER WELLS WITHIN 150' OF THE PROPOSED WORK AREA. <br /> RIGHT OF WAY 1 8. NO WASTEWATER TREATMENT WITHIN 150' OF THE PROPOSED W <br /> ORK <br /> _ 140.1 AREA. <br /> X19.2' 9. NO STORM DRAINS LOCATED ON SITE. <br /> 10. PER CALIFORNIA BUILDING CODE 11 B 203.5, NO ADA PARKING STALL <br /> SPACE IS PROVIDED. <br /> r <br /> 1 200.0' <br /> LEGEND: <br /> � EXISTING BUILDING ., <br /> APPRDX 1,300 5Q FT <br /> CONCRETE DWY TYPE A PER <br /> 1 r, 102.8 <br /> 1 + <br /> 1 mM c r f �..:•:�.i <br /> 1 PROPERTY RSD-G-14A 4 <br /> 1 Irs <br /> BOUNDARY, TYP. m COMMERCIAL SEPTIC <br /> B 11 11 20.0' s BpmsION <br /> ' SYSTEM FOR THREE 1" ALL-WEATHER PERMEABLE <br /> PORTION STRUCTURES: 70'X 120' <br /> "p3/41 LOT B <br /> A, I„-,,-,f CRUSHED ROCK <br /> 1 1 EXISTING BUILDING <br /> 11 � EXISTING RESIDENTIAL -�;` � 1" ALL-WEATHER PERMEABLE <br /> APPROx 2,400 SQ FT 1'�. PROPERTY <br /> 1 1 AND AGRICULTURAL AREA "' BOUNDARY, TYP. <br /> 1 � EXISTING ��•,� CRUSHED RUCK TO RESTS <br /> 1 1 PAVED AREA t'� 120.9' HS-25 LOADING <br /> ASPHALT <br /> REMOVE <br /> 1 11 IS,: TREES <br /> �. EXTEND PAVED k <br /> 1 ` AREA FOR ear 1"1 <br /> ACCESS ROAD 1215 EXISTING DRIVEWAY <br /> 1:� <br /> 1119,0' 100°/° REPLACEMENT <br /> AREA FOR COMMERCIAL <br /> 1 1 n =1SEPTIC SYSTEM FOR <br /> l 11 "� •:1 16'6 cry THREE STRUCTURES: //0\1\ PROPOSED AREA OF WORK <br /> 70'X 1201 <br /> C 1 ": <br /> 1 - CO <br /> - 0KEYED NOTES: <br /> EXISTING//0\1 �, <br /> 1 1 �,� WASTEWATER <br /> EXISTING BUILDING n� SEPTIC AND1 . 7' HIGH CHAIN LINK FENCE WITH NOISE ABSORPTION SLATS ON THE SOUTH, <br /> APPROX 3,100 SD FT S f - - 140.25.0' S LEECH LINES EAST AND NORTH PORTIONS ONLY. <br /> PGG ,:-. ,�:`"�° �' <br /> 1119.0'\ "'GO �' a 2�'0 11a'x 54' 3 STRAND BARBED WIRE ONLY ON SOUTH AND EAST. NO BARBED WIRE <br /> r ► S ELECTRICAL <br /> 10.0 <br /> PGG�E SUBSTATION BETWEEN THE RESIDENCE AND THE PROJECT (NORTH). <br /> 1 GP <br /> ' 1 <br /> ' r . �� LANA MV SWITCHGEAR <br /> 1 20' X 8' PARKING 150` � R <br /> SPOT(TYPICAL OF 3) 1111 - `1 D PER1M �,oN�1 OPTION 2: POLE AND �. [P 40'X& BATTERY <br /> 1 1 OVERHEAD POWER LINES <br /> 01 CONTAINER <br /> 1 { ,� <br /> 11 1 TO INTERCONNECTION (TYPICAL OF 38)1 <br /> 1 ON-SITE WATER TANK, APPROX. 1 �� 20' X 6' POWER <br /> j <br /> 1 1 15,000 GALLON CAPACITY, WITH A CONVERSION <br /> .' <br /> 1 FIRE DEPT. CONNECTION 5.0� 1 �` SYSTEMS (PCS) <br /> 1 1 EXISTING PG&EQ, 15 (TYPICAL OF 18 0� ) EXISTING OPEN <br /> E � <br /> 1 1 POLE <br /> AGRICULTURAL AREA. <br /> 1 1 <br /> 1 25' SETBACK FROM � � •0' <br /> 1 PG&E POLE 7' .0" .01 24.5' NEW FENCING 1❑] <br /> 1 1 <br /> 1 1 OPTION 1: UNDERGROUND 30, 01% �. �^ " <br /> 1 1 POWER LINES TO 10. �^ .� too 00.uf�o <br /> 1 11 a1 INTERCONNECTIONR. <br /> PROPOSED <br /> 1Ic <br /> Li - 5 AREA OF WORK <br /> 1 .0' <br /> fl � 0' 50 100 <br /> EXISTING � -or �wo NORTH SCALE 1"=50' <br /> PG&E DOC► lv , <br /> FENCING 9202896l :'rte <br /> v <br /> EXISTING PG&E Y '� <br /> SUBSTATIONNOT F O R <br /> Y <br /> VTI <br /> E .�6 CONSTRUCTION <br /> J .0.� t�1 W <br /> 01 1-29-20 5P CORRECTIONS <br /> 1 CASCADE BESS �a <br /> 1 •'' Z`` 4a' X 8'AUXILIARIES 00 11-08-19 SP FOR PERMITTING <br /> PROJECT SITE -� ,� <br /> ZONE: RIL r, p C� CONTAINER <br /> 1 �y s6� DATE SCOPE REVISION DESCRiPTIpN PRfPbRElI BY COOPERATIONS APPROVED 8Y ISSUED 8Y <br /> EXISTING PG&E �,�� '�° - Dote Scope Descr+zione della renis+one Prep°rala Colloborozioni Approvato Emessa <br /> POLE r CuErrr <br /> Gliente rNEI. GLOBAL THERMAL GENERATION r � <br /> 25' SETBACK FROM W, n <br /> 25' <br /> PG&E POLE m SETBACK FROM JOB N10 oar Na <br /> V g N'•. d" EMPLOYER S L <br /> PG&E TOWER PROJECT -ASCADE CALIFORNIA Invla aI clients <br /> Progetta ; - -ROY STORAGE SYSTEM (BEBS) ❑ Peerr PoppProvoxone <br /> 99 " to P =Ir!; TITLE ❑ info lommigm <br /> ❑ <br /> 1 T;taro NOTREQUESTEDr, t <br /> 1 � <br /> 1 PRELIMINARY LAYOUT Mon SYSTEM Sistemo <br /> 7 <br /> F , 1 ENGINEER: <br /> ` seziorri SHEET FOLL-SHEET OF SIZE DWG TYPE DISC. <br /> 1 ' 1 -. ` 1.50 DWG rNo F fro ue fl- f7� fORAy4Tt) _ e!- D+'se- <br /> 94 208.7 AECOM TECHNICAL SERVICES, INC __j,a 1 2 24°x36 <br /> 401 WEST A STREET, SUITE 1200 =-- 4AME REPI.A,:ES IYK No REPLACED BY DWG No SEC. INDEX <br /> rk Sost;Ewsce it 5v btuifo dot <br /> 1 ` .�11' 1 EXISTING PG&E SAN DIEGO CA 92101 <br /> 1 N f TY MAP 'k5 DDCt1t1ENT+5 PROPERTY OF fns! Spa- Ouesto docume rte i fo rpetd En c Spn. <br /> VICINITY <br /> � 1 ' STRICTLY FOROMN TO REP'RDOt.CE TkG DOCUMENT WHOLLY pR PRRTtaLLY AND E'saveromente proibrfn rProdurce onche parte it documento o dwrgore <br /> LATTICE STRUCTURE <br /> 1 1 ����� a$, �� TEL 619.610.76 0 0 FAX 619.fi 10.?5 01 -_.*OODE ANY RELATED fWDRPOFOV M 0WR5 9THo9jT PREN[fi15 MWTTV=ENT ad a1tr+k irtformaziani contenvte Benzo Jo preveatiw outorizzariaina scritta. <br /> 1 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.