Laserfiche WebLink
Building , Mechanical , Plumbing , Electrical , Energy and Fire Codes as may be applicable . Plans <br /> for the different buildings or structures may be combined into a single set of construction <br /> documents . <br /> 2 . A grading permit will be required for this project . Submit plans and grading calculations , including <br /> a statement of the estimated quantities of excavation and fill , prepared by a Registered Design <br /> Professional . The grading plan shall show the existing grade and finished grade in contour <br /> intervals of sufficient clarity to indicate the nature and extent of the work and show in detail that it <br /> complies with the requirements of the code . The plans shall show the existing grade on adjoining <br /> properties in sufficient detail to identify how grade changes will conform to the requirements of the <br /> code . <br /> 3 . The required plans must be complete at the time of submittal for a building permit . Plans must <br /> address building design and construction , fire and life safety requirements , accessibility and show <br /> compliance with the current California codes and San Joaquin County ordinances . A complete <br /> set of plans must include fire sprinkler plans , truss design submittals , metal building shop <br /> drawings , structural plans and calculations , plumbing , electrical and mechanical drawings and <br /> energy report . <br /> 4 . A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix § J104 for <br /> grading . All recommendations of the Soils Report shall be incorporated into the construction <br /> drawings . <br /> 5 . For each proposed new building , provide the following information on the plans : <br /> A . Description of proposed use <br /> B . Existing and proposed occupancy Groups <br /> C . Type of construction <br /> D . Sprinklers ( Yes or No ) <br /> E . Number of stories <br /> F . Building height <br /> G . Allowable floor area <br /> H . Proposed floor area <br /> I . Occupant load based on the CBC <br /> J . Occupant load based on the CPC <br /> 6 . Accessible routes shall be provided per CBC § 11 B -206 . At least one ( 1 ) accessible route shall be <br /> provided within the site from accessible parking spaces and accessible passenger loading zones ; <br /> public streets and sidewalks ; and public transportation stops to the accessible building or facility <br /> entrance they serve . Where more than one ( 1 ) route is provided , all routes must be accessible . <br /> § 11 B - 206 . 2 . 1 <br /> 7 . At least one ( 1 ) accessible route shall connect accessible buildings , accessible facilities , <br /> accessible elements and accessible spaces that are on the same site . § 11 B -206 . 2 . 2 <br /> 8 . At least one ( 1 ) accessible route shall connect accessible building or facility entrances with all <br /> accessible spaces and elements within the building or facility , including mezzanines , which are <br /> otherwise connected by a circulation path . § 11 B -206 . 2 . 4 <br /> 9 . Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code . Note that accessible parking spaces are required <br /> for each phase of the project . These parking space ( s ) shall be located as close as possible to the <br /> primary entrance to the building . <br /> 10 . Adequate sanitary facilities shall be provided for the facility , per the requirements of Chapter 4 of <br /> the California Plumbing Code . <br /> PA- 1900301 — Conditions of Approval 3 <br />