Laserfiche WebLink
Chevron Monitoring Certification Checklist <br /> Store Number: 201761 Address : 1103 S . MAIN ST. PERMIT NUMB. W3315 MANTECA, CA 95337 <br /> Date: 1/8/2019 Technician : Jesus Saldivar Company: TANKNOLOGY INC. <br /> Step Instruction T1 Supreme T2 Regular 2 T3 Regular 1 <br /> Product SUPREME REGULAR REGULAR <br /> Tank Type Fiberglass Fiberglass Fiberglass <br /> (DW FRP, DW Steel, SW FRP) <br /> 1 Annular Riser Height ( measured ) 75 .00 in. 76 ,00 in. 75 .00 in. <br /> 2 Tank Diameter: (from tank chart, 92 . 00 in. 92 .00 in. 92 . 00 in. <br /> for example : 118. 375 ", 117. 75 , 111 ",92 ", etc. ) <br /> 3 For FRP tanks, 1/2 circumference of the tank 144 .44 in. 144 .44 in. 144 .44 in. <br /> (0.5 x 3. 14 X tank diam.) OR (q.57 x step 2) <br /> Required annular sensor length : <br /> 4 FRP = Riser + 1/2 Circumference = step 1 + step 3 219 .44 in. 220 .44 in. 219 .44 in. <br /> Steel = Riser + diameter = step 1 + step 2 <br /> Mark & label the required sensor length on <br /> 5 sensor cord . Label should be under the cap & Yes Yes Yes <br /> serve to prevent the cord being pulled too short. <br /> Is tank annular sensor in the correct position ? <br /> Yes Yes Yes <br /> 6 FRP Tanks : with the marked required length <br /> lining up with the top of the annular riser? Yes Yes Yes <br /> Steel Tanks : sensor touching bottom with slack <br /> above the marked required sensor length ? <br /> Are the DW pipe boots pulled back in tank sumps? <br /> 8 (YIN or N/A, note if can 't be verified because Yes Yes Yes <br /> clamshell pointing down) <br /> Are tank sump sensors back in their holders and <br /> 9 in the correct position ? Yes Yes Yes <br /> (YIN or N/A document with photo) <br /> 7 Approximate gallons of product dispensed for <br /> purging, etc . and returned to tank <br /> Has the Veeder Root Battery been replaced & dated prior to failsafe ? <br /> Replaced Today <br /> (If battery backup failed, label and leave failed battery on top of console, note in comments and advise your OM) <br /> Has Veeder Root Programming before & after testing been printed & verified ? Yes <br /> (especially tank manifolding setup - see Note 2) <br /> Has Veeder Root Programming before & after been attached to the Work Order? Yes <br /> Have all sensor model numbers been verified against the Veeder Root cord label ? <br /> Make a note if sensor label missing or illegible, & approx. cord length for -208/-209 with missing labels Yes <br /> i <br /> Additional Comments : <br /> i <br /> Note 1: Certain Veeder Root Software versions will automatically revert to the default tank manifold settings anytime the programming is changed, such as when sensors are <br /> temporarily X'ed out, etc. <br />'`s <br />