Laserfiche WebLink
S A N'J O A Q U I N Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARCO am/pm#83230 1 1340 W Colony Rd Ripon October 22 2019 <br /> Single-Walled Non-Pressurized Piping <br /> 402 CCR 2643(d) Failure to conduct monitoring/maintain records for single-walled conventional suction(pre-1984) ❑V ❑R ❑COS <br /> 403 CCR 2643(d),2661(f) Failure to conduct 0.1 gph test for single-walled conventional suction systems(pre-Jan 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e),2661(f) 0.1-gph line test for single-walled gravity piping not performed biennialy or post repair(pre-1984) ri V R COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V R COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS ll,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. <br /> -The monitoring plans for all tanks incorrectly states that the monitor panel model is a Veer-Root TLS 350.A <br /> Veeder-RootTLS 350 PLUS was observed at the time of the inspection. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System(CERS). Immediately log <br /> into CERS, make the necessary changes,and submit for review by the EHD. <br /> This was corrected on site. <br /> This is a minor violation. <br /> 118 CCR 2715(a)(1)(A), 2715(a)(2) Failure to submit the"Underground Storage Tank Statement of Understanding and <br /> Compliance Form". <br /> The Underground Storage Tank Statement of Understanding and Compliance Form was not found in CERS. This form <br /> must be uploaded to the California Environmental Reporting System(CERS). Immediately log into the California <br /> Environmental Reporting System(CERS)at http://cers.calepa.ca.gov and upload the Underground Storage Tank <br /> Statement of Understanding and Compliance Form for this facility. <br /> This was corrected on site. <br /> This is a minor violation. <br /> 204 CCR 2712(1)Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be accessible <br /> on site at all times. Immediately locate and retain a copy on site. <br /> This was corrected on site. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> FA0019437 PRO529124 SCO01 10/22/2019 <br /> EHD 23-01 Rev.08/27/2019 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />