Laserfiche WebLink
tl <br /> UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page t of 6) <br /> This form must be used to document testing and servicing of underground storage tank (UST) monitoring equipment. A copy <br /> of this form must be provided to the UST owner or operator, The owner or operator must submit a copy of this form to the local <br /> agency regulating the USTs within 30 days of the date of the monitoring system certification . <br /> 1. FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10186995 11 /21 /2018 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) Building # <br /> Chevron <br /> Business Site Address City ZIP Code <br /> 1916 E . March Lane [Stockton 195210 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone # <br /> Nucleus Pump Services (916) 3824761 <br /> Mailing Address <br /> 601 1st Street , Suite B , Sacramento , CA 95818 <br /> Name of UST Service Technician Performing the Certification (Print as shown on the ICC Certification) <br /> Chris Bishop <br /> Contractor I Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 949066 82116429 5/2/2020 <br /> Monitoring System Training and Certifications List all geJeticable certifications. Expiration Date <br /> Veeder Root 6/ 19/2020 <br /> III . RESULTS OF TESTING / SERVICING <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. Y N NA <br /> XD Monitoring System Set-up Alarm History Report <br /> Was any monitoring equipment replaced? 9 ❑ ❑ <br /> (If "Yes, " identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) <br /> Was damage , debris , or liquid found inside any secondary containment systems? <br /> (If "Yes, " describe what was found in section IV below.) <br /> Is all monitoring equipment operational per manufacturer's specifications? O <br /> (If "No, " describe why in section IV below.) <br /> IV. COMMENTS <br /> If directed to use this section, describe how and when the issues were or will be corrected. <br /> THE 87 FILL SUMP SENSOR WAS NOT WORKING THE VEEDER ROOT 208 WAS REPLACED LIKE FOR LIKE AND <br /> RETESTED AND PASSED , S-5 WAS X, ED OUT OF PROGRAMING THE S-5 IS THE DIESEL/91 TANK ANNULAR AFTER <br /> PUTTING THE S-5 VAC SENSOR BACK IN PROGRAMING THE SENSOR WORKED AND PASSED TESTING MADE <br /> REPAIRS TO VAC HOSE AND THE S-5 WAS HOLDING VACUUM AS WELL , I REMOVED LIQUID FROM THE DIESEL <br /> STP SUMP AGOUT 1 GAL , UDC 9- 10 REMOVED FUEL ABOUT 2 GAL. , UDC 11 - 12 REMOVED ABOUT 1 GAL . , UDC <br /> 9- 10 FOUND THAT DIESEL METER END PLATE HAS A SMALL DRIP UDC 9-10 WAS CALLED IN FOR REPAIRS . . <br /> THE S3 VAC LIQUID SENSOR FAILED THE LIQUID TEST, 11 /28/2018 RETURNED WITH THE S3 LIQUID SENSOR AND <br /> REPLACED AND RETESTED THE S-3 LIQUID SENSOR PASSED ALL OK . <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of <br /> Regulations , Title 23, Division 3, Chapter 16 , Section 2638 and all information contained herein is true and accurate. Attached to <br /> this certification is information (e.g . , m nufacturers' checklists , monitoring system set-up, alastory , report, ete } ,necessaiy <br /> to verifythat this information and the e Ian showingthe layout of UST s stem is com le'te ai eurkte = i <br /> UST Service Technician Signature APi <br /> ,. <br /> 17 1 7010 <br /> CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, Y = Yes, N = No, NA = Not Applicable <br /> V1Rl t\! 1VI ' iN� teli. r ErYEk µ <br /> i i €- <br />