My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1916
>
2300 - Underground Storage Tank Program
>
PR0527728
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/18/2020 10:06:34 AM
Creation date
9/18/2020 9:28:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0527728
PE
2351
FACILITY_ID
FA0018792
FACILITY_NAME
MARCH AND BIANCHI INC
STREET_NUMBER
1916
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09603029
CURRENT_STATUS
01
SITE_LOCATION
1916 E MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page 5 of s) <br /> XII . LINE LEAK DETECTOR TESTING <br /> ❑ Check this box if line leak detectors (LLD) are NOT installed . (Do not complete this section.) Y N NA <br /> This section must be completed if LLDs are installed. <br /> Was a leak simulated to verify LLD performance? F] ❑ <br /> (Check all that apply.) Simulated leak rate verified : QX 3 GPH ❑ 0. 1 GPH ❑ 0.2 GPH <br /> Was the testing apparatus properly calibrated ? 0 ❑ ❑ <br /> For emergency generator tank systems , does the LLD create an audible and visual alarm when a leak is detected ? ❑X ❑ ❑ <br /> For mechanical LLDs , does the LLD restrict the flow through the pipe when a leak is detected? ❑ ❑ X❑ <br /> For electronic LLDs, does the turbine automatically shut off when a leak is detected? ❑X ❑ ❑ <br /> For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ❑X ❑ ❑ <br /> For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? ❑X ❑ I ❑ <br /> For electronic LLDs , have all accessible wiring connections been visually inspected for kinks and breaks? ❑X ❑ El <br /> Were all items on the equipment manufacturer's maintenance checklist completed? X❑ ❑ ❑ <br /> Were all LLDs confirmed operational within regulatory requirements? X❑ ❑ I ❑ <br /> For any answer of "N " above, describe in Section X/ll how and when these issues were or will be corrected. <br /> XIII . COMMENTS <br /> XIV. VACUUM / PRESSURE / HYDROSTATIC MONITORING EQUIPMENT TESTING <br /> QX Check this box if VPH monitoring is NOT used. (Do not complete this section.) <br /> This section must be completed if VPH monitoring is used to perform leak detection monitoring. <br /> System Type (Mark all that apply.) X❑ Vacuum ❑ Pressure ❑X Hydrostatic <br /> Sensor ID Component(S) Monitored By This Sensor Sensor Functionality Interstitial Communication <br /> Test Test <br /> S-1 87 PRODUCT ❑X Pass ❑ Fail X❑ Pass ❑ Fail <br /> S-2 ALL VENTSNAPOR ❑X Pass ❑ Fail ❑X Pass ❑ Fail <br /> S-3 87 ANNULAR ❑X Pass ❑ FailX❑ Pass ❑ Fail <br /> S4 91 PRODUCT ❑X Pass ❑ Fail ❑X Pass ❑ Fail <br /> S-5 91 /DIESEL ANNULAR Q Pass ❑ FailX❑ Pass ❑ Fail <br /> S-6 DIESEL PRODUCT QX Pass ❑ Fail ❑X Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> How was interstitial communication verified ? X❑ Simulated Leak at Far Ends of the Interstitial Space ❑ Visual Inspection <br /> Other Describe the method in section XV below. Gauge <br /> E Was the vacuum or pressure restored to operating levels in all interstitial spaces? X❑ Yes ❑ No (Describe the reason in section XV below.) <br /> For any answer of "Fail" above, describe in Section XV how and when these issues were or will be corrected. <br /> XV. COMMENTS <br /> ON 11 /28/2018 THE S-3 VAC LIQUID SENSOR WAS REPLACED AND RETESTED ALL OK . <br /> GPH = Gallon Per Hour, Y = Yes, N = No, NA = Not Applicable, VPH = Vacuum/Pressure/1-lydrostatic, ID = Identification <br /> r <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.