My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10858
>
2300 - Underground Storage Tank Program
>
PR0526212
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 8:49:58 AM
Creation date
9/18/2020 1:55:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0526212
PE
2351
FACILITY_ID
FA0017737
FACILITY_NAME
CHEVRON STATION #307709*
STREET_NUMBER
10858
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
APN
06602015
CURRENT_STATUS
01
SITE_LOCATION
10858 TRINITY PKWY
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OPW Installation, Operation, and Maintenance Manual, Page 78 Executive Order VR -102-Q <br />STEP 17: INSTALL WARNING PLATE <br />Slide the tie wrap over the warning <br />plate ears and position warning <br />plate against riser pipe approxk <br />mately 1" below the adaptor. <br />Tighten the tie wrap securely. The <br />valve is now fully installed and in <br />operating position. <br />STEP 18: VALVE REMOVAL <br />The valve can be removed for tank I ��` <br />leak testing, inspection, etc., by <br />removing the Rotatable Product <br />Adaptor, the 4" nipple, and the Jack Screw Kit, Figure 17 <br />Reinstall per the above instructions. <br />STEP 19: ELECTRONIC LIQUID LEVEL MONITORING <br />If an electronic level monitor is installed, it must be cali- <br />brated to match the top of the 61 SO valve body, which <br />must correlate with 95% of the actual tank capacity. <br />PREVENTATIVE MAINTENANCE <br />Annually, inspect the flapper in the 61 SO to see that it is <br />open by looking down the drop tube opening. Test the <br />61 SO drop tube seals with CARB procedure TP -201.1 D. <br />If the drop tube seal passes testing, no further mainte- <br />nance is required. If the drop tube fails testing, replace <br />the drop tube seal with OPW PIN: H 11931 M for 4" <br />Tubes. Re -test the 61 SO drop tube with CARB proce- <br />dure TP -201.1 D. If this does not correct the leak the <br />61 SO needs to be replaced.,, <br />CAUTION: Do not insert any foreign object into drop <br />tube if flapper is in the closed position. For example <br />a tank level measuring stick. This will damage the <br />valve and void the Warranty. ALWAYS check flapper <br />location before "sticking" the tank. If flapper is in <br />the closed position the tank is either over filled and <br />you need to wait until the liquid level goes down or <br />the 61 SO is damaged and needs to be replaced. <br />61S0 Performance specifications <br />: <br />This Overfill Prevention Valve has been manufactured <br />anA <br />tested to, and met, the following California specifi- <br />cations. Performance Requirement: Leak rate to be less <br />than or equal to 0.17 CFH @ 2.0" W.C. <br />Torque Specification: <br />Self -Clinching Studs, 5116-8 UN thread, 11.5 ft-Ibs mink <br />mum to 13.5 ft-Ibs maximum. <br />IMPORTANT: Leavetheseinstaliation instructions <br />and maintenance procedures with the station opera- <br />tor. <br />3�.�r.41ac�Gte 'C"�`r"l <br />� f 51� - s' <br />»' R,egvest tts Szet <br />fzty+e Cka!e <br />Product Identification <br />
The URL can be used to link to this page
Your browser does not support the video tag.