610
>
2300 - Underground Storage Tank Program
>
PR0521866
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2020 12:41:21 PM
Creation date
9/21/2020 9:32:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0521866
PE
2371
FACILITY_ID
FA0014852
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
610
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
04745039
CURRENT_STATUS
01
SITE_LOCATION
610 S Cherokee Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
289
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM (Page 1 of 6) <br /> Type of Action ❑Installation Test ®Repair Test ❑Six Month Test [:136 Month Test <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10184805 10/9/2019 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Food 4 Less <br /> Business Site Address City ZIP Code <br /> 610 Cherokee Ln. Lodi 95240 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test(Print as shown on the ICC Certification) Phone# <br /> Eusebio Sousa (707)545-5522 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> Able Maintenance, Inc. -312844 5254516 7/12/2021 <br /> III. SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID:(By tank number,stored product,etc.) A 87 B 91 C D <br /> Tank Containment <br /> Tightness Test Result ❑Pass ❑Fail m NA ❑Pass ❑ Fail m NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Product Piping Containment <br /> Tightness Test Result m Pass ❑Fail ❑NA m Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail m NA ❑Pass ❑Fail m NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail m NA ❑Pass ❑Fail m NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail m NA ❑Pass ❑ Fail m NA ❑ Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Vent Piping Containment <br /> Tightness Test Result ❑Pass ❑ Fail m NA ❑Pass ❑Fail m NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑ Fail 0 NA ❑Pass ❑ Fail m NA ❑Pass ❑Fail ❑ NA ❑Pass ❑Fail ❑NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result m Pass ❑Fail ❑NA m Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail 0 NA ❑Pass ❑Fail m NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Turbine/Product Piping Sump <br /> Tightness Test Result ❑Pass Cl Fail m NA ❑Pass ❑Fail m NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Fill Riser Sump <br /> Tightness Test Result ❑Pass ❑Fail m NA ❑Pass Cl Fail ®NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> VENT/TRANSITION SUMP ID: a b C d <br /> Tightness Test Result ❑Pass ❑Fail m NA ❑Pass ❑Fail m NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> UDC ID: 1 UDC 1/2 2 UDC 3/4 3 UDC 5/6 4 <br /> Tightness Test Result m Pass ❑Fail ❑NA 0 Pass ❑Fail ❑NA m Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> UDC ID: 5 6 7 8 <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> UDC ID: 9 10 11 12 <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑ Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> All items marked"Fail'or"NA"must be explained in their respective"COMMENTS"secti ,, h <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN C G tWiln <br /> I hereby certify that the secondary containment was tested in accordance with C lif o la ons; it a 3,Division <br /> 3,Chapter 16,Section 2637 and all the information contained herein is accurate. <br /> UST Service Technician Signature AA N <br /> CERS=Califomia Environmental Reporting System,ID=Identification,UST=Underground Storage Tank ICC WPPcTtW UDC=Under- <br /> Dispenser Containment n F PA AT nA F NIT <br />
The URL can be used to link to this page
Your browser does not support the video tag.