Laserfiche WebLink
UNDERGROUNDS ORALE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection Z 36 Month Inspection <br /> FACILITY INFORMATION _ . <br /> CERS IQ 10184805 i I Date of Overfill Prevention Equipment inspection <br /> 10 / 10/2018 <br /> i Business Name (Same as Facility Name or DBA-Ooing Business As) <br /> Rancho San Miguel <br /> Business Site Address City ZIP Code <br /> - - _� <br /> Lodi 4`95240 <br /> 610 Cherokee Lane <br /> 11 . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the /CC Certification.) j 7Phoo .� <br /> Raamon Frazier (408 ) 971 -2445 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> i 485184 8020732 2/7/2019 <br /> Overfill Prevention Equipment inspection Training and Certifications (List applicable certifications.) <br /> ViR ( ATG ) - 637362 <br /> r <br /> n ; <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION INOftMAtION _-- <br /> 'Inspection Method r ❑x Manufacturer Guidelines (Specify) : Veeder Root 10U f � <br /> Used: _ <br /> ❑ Industry Code or Engineering Standard (Specify) t <br /> [ V r- 7ft tr,71 s ft L7 <br /> �. � " . <br /> ❑ Engineered Method (Specify): <br /> Attach the Inspection procedures and all documentation required to determine the results. # of Attached Pages <br /> TANK ID : (By tank number, stored product, etc.) T1 - 87 T1 - 91 G _ <br /> What is the tank inside diameter? (Inches) 112.O0 ( 1 12 . 00 <br /> Is the fill piping secondarily contained? ZYes E] No 3 E) Yes ❑ No E) Yes ❑ No CJYes ❑ No <br /> Is the vent piping secondarily contained? i ® Yes ❑ No 9 Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> � <br /> Overfill Prevention Equipment Manufacturer(s) Veeder Root Veeder Root <br /> What is the overfill prevention equipment response ❑ Shuts Off Flow ❑ Shuts Off now ❑ Shuts Off Flow Ii ❑ Shuts Off Flow <br /> when activated ? <br /> (Check all that apply.) E] Restricts Flow EJ Restricts Flow E] Restricts Flow ❑ Restricts Flow <br /> ( Q AiV Alarm O AN Alarm i ❑ AN Alarm " E] AN Alarm <br /> Are flow restrictors installed on vent piping? ❑ Yes [I No E] Yes ❑ No ❑ Yes ❑ No II ❑ Yes E] No i <br /> At what level in the tank is the overfill prevention set ! 1 3027 4568 11 r <br /> to activate? (Inches from bottom of tank.) <br /> What is the percent capacity of the lank at which the <br /> i overfill prevention equipment activates? 90 % _ 90 % ;! <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑x Yes i ElYes El Yes I' <br /> to respond when the substance reaches the <br /> appropriate level? EJ No (Specify in V ) ❑ No (Specify in V ) E] No (Specify in V,) ❑ No (Specifyin V ) <br /> {,.-- <br /> .. n V. <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ® Pass ❑ Fad ® Pass ❑ Fail ❑ Pass ❑ Fail 0 Pass E] Fail <br /> _ _V . COMMENTS _ <br /> Any items marked 'Fal " must be explained in this section. Any additional comments may also be provided here. <br /> i <br /> vim CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> _ _. --- .___ _ . - - _-� _. _ _- __ ._ ___ . <br /> hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations , Title 23, <br /> Division 3, Chapter 16 , Section 2637 .2 and all the information contained herein is accurate , <br /> UST Service Technician Signature <br /> r If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Envin rrnental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = Intematbnal Code Council, AN = Audbte and Usual <br /> E <br /> I <br /> I <br />