My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
610
>
2300 - Underground Storage Tank Program
>
PR0521866
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2020 12:41:21 PM
Creation date
9/21/2020 9:32:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0521866
PE
2371
FACILITY_ID
FA0014852
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
610
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
04745039
CURRENT_STATUS
01
SITE_LOCATION
610 S Cherokee Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
289
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUNDS ORALE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection Z 36 Month Inspection <br /> FACILITY INFORMATION _ . <br /> CERS IQ 10184805 i I Date of Overfill Prevention Equipment inspection <br /> 10 / 10/2018 <br /> i Business Name (Same as Facility Name or DBA-Ooing Business As) <br /> Rancho San Miguel <br /> Business Site Address City ZIP Code <br /> - - _� <br /> Lodi 4`95240 <br /> 610 Cherokee Lane <br /> 11 . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the /CC Certification.) j 7Phoo .� <br /> Raamon Frazier (408 ) 971 -2445 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> i 485184 8020732 2/7/2019 <br /> Overfill Prevention Equipment inspection Training and Certifications (List applicable certifications.) <br /> ViR ( ATG ) - 637362 <br /> r <br /> n ; <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION INOftMAtION _-- <br /> 'Inspection Method r ❑x Manufacturer Guidelines (Specify) : Veeder Root 10U f � <br /> Used: _ <br /> ❑ Industry Code or Engineering Standard (Specify) t <br /> [ V r- 7ft tr,71 s ft L7 <br /> �. � " . <br /> ❑ Engineered Method (Specify): <br /> Attach the Inspection procedures and all documentation required to determine the results. # of Attached Pages <br /> TANK ID : (By tank number, stored product, etc.) T1 - 87 T1 - 91 G _ <br /> What is the tank inside diameter? (Inches) 112.O0 ( 1 12 . 00 <br /> Is the fill piping secondarily contained? ZYes E] No 3 E) Yes ❑ No E) Yes ❑ No CJYes ❑ No <br /> Is the vent piping secondarily contained? i ® Yes ❑ No 9 Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> � <br /> Overfill Prevention Equipment Manufacturer(s) Veeder Root Veeder Root <br /> What is the overfill prevention equipment response ❑ Shuts Off Flow ❑ Shuts Off now ❑ Shuts Off Flow Ii ❑ Shuts Off Flow <br /> when activated ? <br /> (Check all that apply.) E] Restricts Flow EJ Restricts Flow E] Restricts Flow ❑ Restricts Flow <br /> ( Q AiV Alarm O AN Alarm i ❑ AN Alarm " E] AN Alarm <br /> Are flow restrictors installed on vent piping? ❑ Yes [I No E] Yes ❑ No ❑ Yes ❑ No II ❑ Yes E] No i <br /> At what level in the tank is the overfill prevention set ! 1 3027 4568 11 r <br /> to activate? (Inches from bottom of tank.) <br /> What is the percent capacity of the lank at which the <br /> i overfill prevention equipment activates? 90 % _ 90 % ;! <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑x Yes i ElYes El Yes I' <br /> to respond when the substance reaches the <br /> appropriate level? EJ No (Specify in V ) ❑ No (Specify in V ) E] No (Specify in V,) ❑ No (Specifyin V ) <br /> {,.-- <br /> .. n V. <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ® Pass ❑ Fad ® Pass ❑ Fail ❑ Pass ❑ Fail 0 Pass E] Fail <br /> _ _V . COMMENTS _ <br /> Any items marked 'Fal " must be explained in this section. Any additional comments may also be provided here. <br /> i <br /> vim CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> _ _. --- .___ _ . - - _-� _. _ _- __ ._ ___ . <br /> hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations , Title 23, <br /> Division 3, Chapter 16 , Section 2637 .2 and all the information contained herein is accurate , <br /> UST Service Technician Signature <br /> r If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Envin rrnental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = Intematbnal Code Council, AN = Audbte and Usual <br /> E <br /> I <br /> I <br />